AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B EL180UH090XE48B 8259153
14ACXS036-230A TXV 34,000 14.50 12.20 CX35-30B EL195UH045XE36B 8259168
14ACXS036-230A TXV 34,000 15.10 12.50 CX35-30B EL195UH070XE36B 8259156
14ACXS036-230A TXV 34,000 14.50 12.20 CX35-30B EL296UH045XE36B 8259154
14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30B EL296UH045XV36B 8259158
14ACXS036-230A TXV 34,000 15.10 12.50 CX35-30B EL296UH070XE36B 8259146
14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30B EL296UH070XV36B 8259148
14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090V36B 8259149
14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090V48B 8259161
14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090XV48B 8259163
14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30B SLP98UH070XV36B 8259159
14ACXS036-230A TXV 34,000 14.50 12.00 CX35-30B 8259144
14ACXS036-230A TXV 34,400 15.10 12.50 CX35-36A EL180UH045E36A 8259227
14ACXS036-230A TXV 34,400 15.10 12.50 CX35-36A EL180UH045XE36A 8259232
14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36A SL280UH070V36A 8259228
14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36A SL280UH070XV36A 8259230
14ACXS036-230A TXV 34,200 14.50 12.20 CX35-36A 8259225
14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH070E36B 8259253
14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH070XE36B 8259242
14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH090E48B 8259255
14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH090XE48B 8259243
14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL195UH045XE36B 8259257
14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL195UH070XE36B 8259247
14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL296UH045XE36B 8259245
14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36B EL296UH045XV36B 8259248
14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL296UH070XE36B 8259235
14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36B EL296UH070XV36B 8259237
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090V36B 8259239
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090V48B 8259252
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090XV48B 8259240
14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36B SLP98UH070XV36B 8259250
14ACXS036-230A TXV 34,200 14.25 12.20 CX35-36B 8259233
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH070E36B 8259262
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH070XE36B 8259282
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH090E48B 8259263
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH090XE48B 8259269
14ACXS036-230A TXV 34,400 15.00 12.50 CX35-48B EL195UH045XE36B 8259271
14ACXS036-230A TXV 34,600 15.10 12.50 CX35-48B EL195UH070XE36B 8259274
14ACXS036-230A TXV 34,400 15.00 12.50 CX35-48B EL296UH045XE36B 8259273
14ACXS036-230A TXV 34,800 15.50 12.50 CX35-48B EL296UH045XV36B 8259278
14ACXS036-230A TXV 34,600 15.10 12.50 CX35-48B EL296UH070XE36B 8259276
14ACXS036-230A TXV 34,800 15.50 12.50 CX35-48B EL296UH070XV36B 8259265
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B SL280UH090V36B 8259279
14ACXS036-230A TXV 35,000 16.00 13.00 CX35-48B SL280UH090V48B 8259260
14ACXS036-230A TXV 35,000 16.00 13.00 CX35-48B SL280UH090XV48B 8259281
14ACXS036-230A TXV 34,800 15.50 12.50 CX35-48B SLP98UH070XV36B 8259267
14ACXS036-230A TXV 34,400 14.50 12.20 CX35-48B 8259258
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH090E60C 8259314
14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH110E60C 8259316
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.