14ACX - 1.5 to 5 Ton Air Conditioner / Page 109
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XV60C 7627394
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XE60C 7782912
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XV48C 7627397
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XV60C 7782913
14ACXS042-230A TXV 41,500 15.10 12.50 C33-50/60C SL280UH090V60C 7627400
14ACXS042-230A TXV 41,500 15.10 12.50 C33-50/60C SL280UH090XV60C 7782914
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SL280UH110V60C 7627403
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SL280UH110XV60C 7782915
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV36C 7627406
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV48C 7782916
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV60C 7627409
14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH110XV60C 7782917
14ACXS042-230A TXV 40,500 14.25 12.00 C33-50/60C 7782907
14ACXS042-230A TXV 42,000 16.00 13.00 C33-60D EL180UH135E60D 7782918
14ACXS042-230A TXV 42,000 15.50 12.50 C33-60D EL195UH135XE60D 7627415
14ACXS042-230A TXV 42,000 15.50 12.50 C33-60D EL296UH135XE60D 7782919
14ACXS042-230A TXV 42,000 16.00 13.00 C33-60D SL280UH135V60D 7627418
14ACXS042-230A TXV 41,000 14.25 12.00 C33-60D 7627412
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH090E60C 7782921
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH110E60C 7627424
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH110XE60C 7782922
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL195UH090XE48C 7627427
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL195UH110XE60C 7782923
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH090XE48C 7627430
14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C EL296UH090XV36C 7782924
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH090XV48C 7627433
14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C EL296UH090XV60C 7782925
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XE60C 7627436
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XV48C 7782926
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XV60C 7627439
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH090V60C 7782927
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH090XV60C 7627442
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH110V60C 7782928
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH110XV60C 7627446
14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C SLP98UH090XV36C 7782929
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SLP98UH090XV48C 7627449
14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C SLP98UH090XV60C 7782930
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SLP98UH110XV60C 7627452
14ACXS042-230A TXV 42,000 14.25 12.20 C33-62C 7627421
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62D EL180UH135E60D 7627455
14ACXS042-230A TXV 42,000 15.50 12.50 C33-62D EL195UH135XE60D 7782932
14ACXS042-230A TXV 42,000 15.50 12.50 C33-62D EL296UH135XE60D 7627458
14ACXS042-230A TXV 42,000 16.00 13.00 C33-62D SL280UH135V60D 7782933
14ACXS042-230A TXV 41,500 14.25 12.20 C33-62D 7782931
14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B EL180UH090E48B 8258241
14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B EL180UH090XE48B 8258236
14ACXS042-230A TXV 39,000 14.00 11.50 C35-30/36B EL296UH045XV36B 8258233
14ACXS042-230A TXV 39,000 14.00 11.50 C35-30/36B EL296UH070XV36B 8258234
14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B SL280UH090V36B 8258243
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.