AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH110XV60C 7627725
14ACXS042-230A TXV 42,000 16.00 13.00 CH35-42C SL280UH090V60C 7783011
14ACXS042-230A TXV 42,000 16.00 13.00 CH35-42C SL280UH090XV60C 7627728
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SL280UH110V60C 7783012
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SL280UH110XV60C 7627731
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH090XV36C 7783013
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH090XV48C 7627734
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42C SLP98UH090XV60C 7783014
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH110XV60C 7627737
14ACXS042-230A TXV 41,500 14.00 12.20 CH35-42C 7627707
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48B EL180UH090E48B 7783015
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48B EL180UH090XE48B 7627740
14ACXS042-230A TXV 41,000 14.50 12.20 CH35-48B EL296UH045XV36B 7783016
14ACXS042-230A TXV 41,000 14.50 12.20 CH35-48B EL296UH070XV36B 7627743
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090V36B 7783017
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090V48B 7627746
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090XV48B 7783018
14ACXS042-230A TXV 41,000 14.50 12.20 CH35-48B SLP98UH070XV36B 7627749
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH090E60C 7627752
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH110E60C 7783020
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH110XE60C 7627755
14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C EL195UH090XE48C 7783021
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL195UH110XE60C 7627758
14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C EL296UH090XE48C 7783023
14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C EL296UH090XV36C 7627761
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH090XV48C 7783024
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH090XV60C 7627764
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH110XE60C 7783025
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL296UH110XV48C 7627767
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH110XV60C 7783026
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C SL280UH090V60C 7627770
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C SL280UH090XV60C 7783027
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SL280UH110V60C 7627773
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SL280UH110XV60C 7783028
14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C SLP98UH090XV36C 7627776
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH090XV48C 7783029
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH090XV60C 7627779
14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH110XV60C 7783030
14ACXS042-230A TXV 41,500 14.00 12.20 CH35-48C 7783019
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH090E60C 7783031
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH110E60C 7627786
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH110XE60C 7783032
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-51C EL195UH090XE48C 7627789
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL195UH110XE60C 7783033
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-51C EL296UH090XE48C 7627792
14ACXS042-230A TXV 41,500 15.50 12.50 CH35-51C EL296UH090XV36C 7783034
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH090XV48C 7627795
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH090XV60C 7783035
14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH110XE60C 7627798
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Related product manuals