AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL180UH110XE60C 7486538
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL195UH090XE48C 7486528
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL195UH110XE60C 7486530
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL296UH090XE48C 7486529
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL296UH090XV48C 7486532
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL296UH090XV60C 7486533
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL296UH110XE60C 7486531
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL296UH110XV48C 7486534
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL296UH110XV60C 7486535
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH090V60C 7486539
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH090XV60C 7486540
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH110V60C 7486541
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH110XV60C 7486542
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C SLP98UH090XV48C 7486543
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C SLP98UH090XV60C 7486544
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C SLP98UH110XV60C 7486545
14ACX-048-230 TXV 48,000 14.00 11.70 CH33-50/60C 7486527
14ACX-048-230 TXV 48,000 15.00 12.50 CH33-60D EL180UH135E60D 7486549
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-60D EL195UH135XE60D 7486546
14ACX-048-230 TXV 48,000 14.25 12.00 CH33-60D EL296UH135XE60D 7486547
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-60D EL296UH135XV60D 7486548
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-60D SL280UH135V60D 7486550
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-60D SLP98UH135XV60D 7486551
14ACX-048-230 TXV 48,000 15.00 12.50 CH33-62D EL180UH135E60D 7486556
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D EL195UH135XE60D 7486553
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D EL296UH135XE60D 7486554
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D EL296UH135XV60D 7486555
14ACX-048-230 TXV 48,000 15.00 12.50 CH33-62D SL280UH135V60D 7486557
14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D SLP98UH135XV60D 7486558
14ACX-048-230 TXV 48,000 14.00 11.70 CH33-62D 7486552
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42B EL180UH090E48B 7486559
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42B EL180UH090XE48B 7486560
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C EL180UH090E60C 7486569
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL180UH110E60C 7486570
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL180UH110XE60C 7486571
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL195UH090XE48C 7486561
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C EL195UH110XE60C 7486563
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH090XE48C 7486562
14ACX-048-230 TXV 48,000 14.25 11.70 CH35-42C EL296UH090XV48C 7486565
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH090XV60C 7486566
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C EL296UH110XE60C 7486564
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH110XV48C 7486567
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH110XV60C 7486568
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH090V60C 7486572
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH090XV60C 7486573
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH110V60C 7486574
14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH110XV60C 7486575
14ACX-048-230 TXV 48,000 14.25 11.70 CH35-42C SLP98UH090XV48C 7486576
14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C SLP98UH090XV60C 7486577
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.