14ACX - 1.5 to 5 Ton Air Conditioner / Page 37
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 EL180UH090E60C 7486685
14ACX-048-230 TXV 48,000 15.00 12.00 CX34-49 EL180UH110E60C 7486686
14ACX-048-230 TXV 48,000 15.00 12.00 CX34-49 EL180UH110XE60C 7486687
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL195UH090XE48C 7486677
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL195UH110XE60C 7486679
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH090XE48C 7486678
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH090XV48C 7486681
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH090XV60C 7486682
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH110XE60C 7486680
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH110XV48C 7486683
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH110XV60C 7486684
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH090V60C 7486688
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH090XV60C 7486689
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH110V60C 7486690
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH110XV60C 7486691
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 SLP98UH090XV48C 7486692
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 SLP98UH090XV60C 7486693
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 SLP98UH110XV60C 7486694
14ACX-048-230 TXV 48,000 14.00 11.70 CX34-49 7486676
14ACX-048-230 TXV 47,500 14.50 12.00 CX34-50/60C EL180UH090E60C 7486703
14ACX-048-230 TXV 48,000 14.00 11.70 CX34-50/60C EL180UH110E60C 7486704
14ACX-048-230 TXV 48,000 14.00 11.70 CX34-50/60C EL180UH110XE60C 7486705
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL195UH090XE48C 7486695
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL195UH110XE60C 7486697
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL296UH090XE48C 7486696
14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C EL296UH090XV48C 7486699
14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C EL296UH090XV60C 7486700
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL296UH110XE60C 7486698
14ACX-048-230 TXV 47,500 14.25 11.70 CX34-50/60C EL296UH110XV48C 7486701
14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C EL296UH110XV60C 7486702
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH090V60C 7486706
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH090XV60C 7486707
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH110V60C 7486708
14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH110XV60C 7486709
14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C SLP98UH090XV48C 7486710
14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C SLP98UH090XV60C 7486711
14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C SLP98UH110XV60C 7486712
14ACX-048-230 TXV 48,000 14.50 12.50 CX34-60D EL180UH135E60D 7486717
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D EL195UH135XE60D 7486714
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D EL296UH135XE60D 7486715
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D EL296UH135XV60D 7486716
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-60D SL280UH135V60D 7486718
14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D SLP98UH135XV60D 7486719
14ACX-048-230 TXV 48,000 14.00 11.70 CX34-60D 7486713
14ACX-048-230 TXV 48,000 15.10 12.50 CX34-62C EL180UH090E60C 7486729
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL180UH110E60C 7486730
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL180UH110XE60C 7486731
14ACX-048-230 TXV 48,000 14.50 12.50 CX34-62C EL195UH090XE48C 7486721
14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL195UH110XE60C 7486723
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.