14ACX - 1.5 to 5 Ton Air Conditioner / Page 40
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-048-230 TXV 48,000 14.25 12.00 CX35-60D EL195UH135XE60D 8267683
14ACX-048-230 TXV 48,000 14.25 12.00 CX35-60D EL296UH135XE60D 8267685
14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60D EL296UH135XV60D 8267684
14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60D SL280UH135V60D 8267687
14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60D SLP98UH135XV60D 8267682
14ACX-048-230 TXV 48,000 14.00 11.70 CX35-60D 8267681
14ACX-059-230 TXV 56,500 15.00 12.20 C33-49 EL180UH090E60C 5736411
14ACX-059-230 TXV 56,500 15.00 12.20 C33-49 EL180UH110E60C 5738227
14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 EL180UH110XE60C 5739166
14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 EL195UH110XE60C 5053221
14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 EL296UH110XE60C 5648039
14ACX-059-230 TXV 56,500 14.70 12.00 C33-49 EL296UH110XV60C 5431226
14ACX-059-230 TXV 56,500 15.00 12.20 C33-49 SL280UH090V60C 5053154
14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 SL280UH110V60C 5053155
14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 SL280UH110XV60C 5053156
14ACX-059-230 TXV 57,000 14.50 12.00 C33-49 SLP98UH090XV60C 5141539
14ACX-059-230 TXV 56,500 14.70 12.00 C33-49 SLP98UH110XV60C 5141540
14ACX-059-230 TXV 57,000 14.50 12.00 C33-49 5053098
14ACX-059-230 TXV 56,000 14.00 11.70 C33-50/60C EL180UH110E60C 5738229
14ACX-059-230 TXV 55,500 14.50 12.00 C33-50/60C SL280UH090V60C 5053161
14ACX-059-230 TXV 55,500 14.20 12.00 C33-50/60C SL280UH110V60C 5053162
14ACX-059-230 TXV 55,500 14.20 12.00 C33-50/60C SL280UH110XV60C 5053163
14ACX-059-230 TXV 55,500 14.20 11.70 C33-50/60C SLP98UH110XV60C 5141542
14ACX-059-230 TXV 55,500 14.20 11.70 C33-50/60C 5053099
14ACX-059-230 TXV 57,000 15.00 12.20 C33-60D EL180UH135E60D 5746022
14ACX-059-230 TXV 56,500 14.20 12.00 C33-60D EL195UH135XE60D 5053226
14ACX-059-230 TXV 56,500 14.20 12.00 C33-60D EL296UH135XE60D 5648044
14ACX-059-230 TXV 57,000 15.00 12.20 C33-60D EL296UH135XV60D 5431227
14ACX-059-230 TXV 57,000 14.70 12.20 C33-60D SL280UH135V60D 5053123
14ACX-059-230 TXV 56,500 15.00 12.20 C33-60D SLP98UH135XV60D 5141551
14ACX-059-230 TXV 56,500 14.50 12.00 C33-60D 5053100
14ACX-059-230 TXV 58,000 15.50 12.70 C33-62C EL180UH090E60C 5736414
14ACX-059-230 TXV 57,500 15.20 12.50 C33-62C EL180UH110E60C 5738231
14ACX-059-230 TXV 57,500 14.70 12.20 C33-62C EL180UH110XE60C 5739178
14ACX-059-230 TXV 58,000 15.40 12.50 C33-62C EL195UH110XE60C 5053222
14ACX-059-230 TXV 58,000 15.40 12.50 C33-62C EL296UH110XE60C 5648040
14ACX-059-230 TXV 57,500 15.00 12.20 C33-62C EL296UH110XV60C 5431229
14ACX-059-230 TXV 58,000 15.20 12.50 C33-62C SL280UH090V60C 5053182
14ACX-059-230 TXV 58,000 14.70 12.20 C33-62C SL280UH110V60C 5053183
14ACX-059-230 TXV 58,000 14.70 12.20 C33-62C SL280UH110XV60C 5053184
14ACX-059-230 TXV 58,000 14.70 12.20 C33-62C SLP98UH090XV60C 5141547
14ACX-059-230 TXV 57,500 15.00 12.20 C33-62C SLP98UH110XV60C 5141548
14ACX-059-230 TXV 57,500 14.70 12.20 C33-62C 5053095
14ACX-059-230 TXV 57,500 15.10 12.50 C33-62D EL180UH135E60D 5746023
14ACX-059-230 TXV 57,500 14.50 12.20 C33-62D EL195UH135XE60D 5053245
14ACX-059-230 TXV 57,500 14.50 12.20 C33-62D EL296UH135XE60D 5648053
14ACX-059-230 TXV 57,500 15.00 12.50 C33-62D EL296UH135XV60D 5433293
14ACX-059-230 TXV 57,000 15.50 12.70 C33-62D SL280UH135V60D 5053188
14ACX-059-230 TXV 57,000 14.50 12.00 C33-62D 5053096
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.