EasyManua.ls Logo

Lennox 14ACx–024-230A02 - Page 42

Lennox 14ACx–024-230A02
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14ACX - 1.5 to 5 Ton Air Conditioner / Page 42
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-059-230 TXV 56,500 14.50 12.20 CBX32M-060 5053120
14ACX-059-230 TXV 55,500 14.70 12.00 CBX32MV-048 5053121
14ACX-059-230 TXV 56,500 14.70 12.20 CBX32MV-060 5053122
14ACX-059-230 TXV 56,000 14.70 12.00 CBX32MV-068 5053103
14ACX-059-230 TXV 56,000 15.00 12.20 CBX40UHV-048 5053104
14ACX-059-230 TXV 56,500 14.70 12.20 CBX40UHV-060 5053105
14ACX-059-230 TXV 57,500 15.20 12.50 CH23-68 EL180UH135E60D 5746024
14ACX-059-230 TXV 57,500 14.70 12.20 CH23-68 EL195UH135XE60D 5053227
14ACX-059-230 TXV 57,500 14.70 12.20 CH23-68 EL296UH135XE60D 5648045
14ACX-059-230 TXV 57,000 14.50 12.50 CH23-68 5053089
14ACX-059-230 TXV 57,000 15.00 12.50 CH33-49 EL180UH090E60C 5736415
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL180UH110E60C 5738234
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL180UH110XE60C 5739170
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL195UH110XE60C 5053223
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL296UH110XE60C 5648041
14ACX-059-230 TXV 57,000 15.00 12.20 CH33-49 SL280UH090V60C 5053108
14ACX-059-230 TXV 57,000 14.70 12.00 CH33-49 SL280UH110V60C 5053109
14ACX-059-230 TXV 57,000 14.70 12.00 CH33-49 SL280UH110XV60C 5053128
14ACX-059-230 TXV 57,000 14.50 12.00 CH33-49 SLP98UH090XV60C 5141552
14ACX-059-230 TXV 57,500 14.20 11.70 CH33-50/60C EL180UH090E60C 5736418
14ACX-059-230 TXV 57,500 14.20 12.00 CH33-50/60C EL180UH110E60C 5738219
14ACX-059-230 TXV 57,500 14.00 12.20 CH33-50/60C EL180UH110XE60C 5739181
14ACX-059-230 TXV 57,000 14.20 11.70 CH33-50/60C EL195UH110XE60C 5053224
14ACX-059-230 TXV 57,000 14.20 11.70 CH33-50/60C EL296UH110XE60C 5648042
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-50/60C SL280UH090V60C 5053131
14ACX-059-230 TXV 56,000 14.50 12.00 CH33-50/60C SL280UH110V60C 5053132
14ACX-059-230 TXV 56,000 14.50 12.00 CH33-50/60C SL280UH110XV60C 5053133
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-60D EL180UH135E60D 5746017
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-60D EL195UH135XE60D 5053228
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-60D EL296UH135XE60D 5648046
14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D EL296UH135XV60D 5431234
14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D SL280UH135V60D 5053168
14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D SLP98UH135XV60D 5141543
14ACX-059-230 TXV 56,000 14.50 11.70 CH33-60D 5053101
14ACX-059-230 TXV 57,000 15.00 12.20 CH33-62D EL180UH135E60D 5746018
14ACX-059-230 TXV 57,000 14.50 12.00 CH33-62D EL195UH135XE60D 5053229
14ACX-059-230 TXV 57,000 14.50 12.00 CH33-62D EL296UH135XE60D 5648047
14ACX-059-230 TXV 57,000 15.00 12.20 CH33-62D EL296UH135XV60D 5431235
14ACX-059-230 TXV 57,000 14.70 12.20 CH33-62D SL280UH135V60D 5053174
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-62D SLP98UH135XV60D 5141544
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-62D 5053102
14ACX-059-230 TXV 58,000 14.50 12.00 CH35-51C EL180UH090E60C 7163557
14ACX-059-230 TXV 58,000 14.50 12.00 CH35-51C EL180UH110E60C 7163558
14ACX-059-230 TXV 57,500 14.25 11.70 CH35-51C EL195UH110XE60C 7163555
14ACX-059-230 TXV 57,500 14.25 11.70 CH35-51C EL296UH110XE60C 7163556
14ACX-059-230 TXV 57,500 14.50 12.00 CH35-51C SL280UH090V60C 7163559
14ACX-059-230 TXV 56,500 14.50 12.00 CH35-51C SL280UH110V60C 7163560
14ACX-059-230 TXV 56,500 14.50 12.00 CH35-51C SL280UH110XV60C 7163561
14ACX-059-230 TXV 57,000 14.50 12.00 CH35-51C SLP98UH090XV60C 7163554
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.