14ACX - 1.5 to 5 Ton Air Conditioner / Page 42
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-059-230 TXV 56,500 14.50 12.20 CBX32M-060 5053120
14ACX-059-230 TXV 55,500 14.70 12.00 CBX32MV-048 5053121
14ACX-059-230 TXV 56,500 14.70 12.20 CBX32MV-060 5053122
14ACX-059-230 TXV 56,000 14.70 12.00 CBX32MV-068 5053103
14ACX-059-230 TXV 56,000 15.00 12.20 CBX40UHV-048 5053104
14ACX-059-230 TXV 56,500 14.70 12.20 CBX40UHV-060 5053105
14ACX-059-230 TXV 57,500 15.20 12.50 CH23-68 EL180UH135E60D 5746024
14ACX-059-230 TXV 57,500 14.70 12.20 CH23-68 EL195UH135XE60D 5053227
14ACX-059-230 TXV 57,500 14.70 12.20 CH23-68 EL296UH135XE60D 5648045
14ACX-059-230 TXV 57,000 14.50 12.50 CH23-68 5053089
14ACX-059-230 TXV 57,000 15.00 12.50 CH33-49 EL180UH090E60C 5736415
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL180UH110E60C 5738234
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL180UH110XE60C 5739170
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL195UH110XE60C 5053223
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL296UH110XE60C 5648041
14ACX-059-230 TXV 57,000 15.00 12.20 CH33-49 SL280UH090V60C 5053108
14ACX-059-230 TXV 57,000 14.70 12.00 CH33-49 SL280UH110V60C 5053109
14ACX-059-230 TXV 57,000 14.70 12.00 CH33-49 SL280UH110XV60C 5053128
14ACX-059-230 TXV 57,000 14.50 12.00 CH33-49 SLP98UH090XV60C 5141552
14ACX-059-230 TXV 57,500 14.20 11.70 CH33-50/60C EL180UH090E60C 5736418
14ACX-059-230 TXV 57,500 14.20 12.00 CH33-50/60C EL180UH110E60C 5738219
14ACX-059-230 TXV 57,500 14.00 12.20 CH33-50/60C EL180UH110XE60C 5739181
14ACX-059-230 TXV 57,000 14.20 11.70 CH33-50/60C EL195UH110XE60C 5053224
14ACX-059-230 TXV 57,000 14.20 11.70 CH33-50/60C EL296UH110XE60C 5648042
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-50/60C SL280UH090V60C 5053131
14ACX-059-230 TXV 56,000 14.50 12.00 CH33-50/60C SL280UH110V60C 5053132
14ACX-059-230 TXV 56,000 14.50 12.00 CH33-50/60C SL280UH110XV60C 5053133
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-60D EL180UH135E60D 5746017
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-60D EL195UH135XE60D 5053228
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-60D EL296UH135XE60D 5648046
14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D EL296UH135XV60D 5431234
14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D SL280UH135V60D 5053168
14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D SLP98UH135XV60D 5141543
14ACX-059-230 TXV 56,000 14.50 11.70 CH33-60D 5053101
14ACX-059-230 TXV 57,000 15.00 12.20 CH33-62D EL180UH135E60D 5746018
14ACX-059-230 TXV 57,000 14.50 12.00 CH33-62D EL195UH135XE60D 5053229
14ACX-059-230 TXV 57,000 14.50 12.00 CH33-62D EL296UH135XE60D 5648047
14ACX-059-230 TXV 57,000 15.00 12.20 CH33-62D EL296UH135XV60D 5431235
14ACX-059-230 TXV 57,000 14.70 12.20 CH33-62D SL280UH135V60D 5053174
14ACX-059-230 TXV 56,500 15.00 12.20 CH33-62D SLP98UH135XV60D 5141544
14ACX-059-230 TXV 56,500 14.50 12.00 CH33-62D 5053102
14ACX-059-230 TXV 58,000 14.50 12.00 CH35-51C EL180UH090E60C 7163557
14ACX-059-230 TXV 58,000 14.50 12.00 CH35-51C EL180UH110E60C 7163558
14ACX-059-230 TXV 57,500 14.25 11.70 CH35-51C EL195UH110XE60C 7163555
14ACX-059-230 TXV 57,500 14.25 11.70 CH35-51C EL296UH110XE60C 7163556
14ACX-059-230 TXV 57,500 14.50 12.00 CH35-51C SL280UH090V60C 7163559
14ACX-059-230 TXV 56,500 14.50 12.00 CH35-51C SL280UH110V60C 7163560
14ACX-059-230 TXV 56,500 14.50 12.00 CH35-51C SL280UH110XV60C 7163561
14ACX-059-230 TXV 57,000 14.50 12.00 CH35-51C SLP98UH090XV60C 7163554
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.