14ACX - 1.5 to 5 Ton Air Conditioner / Page 98
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A TXV 36,000 16.00 13.00 CH35-51C SL280UH090XV60C 7626882
14ACXS036-230A TXV 35,800 16.00 13.00 CH35-51C SL280UH110V60C 7782768
14ACXS036-230A TXV 35,800 16.00 13.00 CH35-51C SL280UH110XV60C 7626885
14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C SLP98UH090XV36C 7782773
14ACXS036-230A TXV 35,200 16.00 13.00 CH35-51C SLP98UH090XV48C 7782774
14ACXS036-230A TXV 35,800 16.00 13.00 CH35-51C SLP98UH110XV60C 7626906
14ACXS036-230A TXV 34,800 14.50 12.20 CH35-51C 7626877
14ACXS036-230A TXV 33,600 14.50 12.20 CR33-30/36A EL180DF045E36A 7626909
14ACXS036-230A TXV 33,600 15.00 12.50 CR33-30/36A SL280DF070V36A 7782776
14ACXS036-230A TXV 33,600 15.50 12.50 CR33-30/36B EL180DF070E36B 7782778
14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL180DF090E48B 7626916
14ACXS036-230A TXV 33,400 14.50 12.00 CR33-30/36B EL195DF045XE36B 7782779
14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL195DF070XE48B 7782780
14ACXS036-230A TXV 33,400 14.50 12.00 CR33-30/36B EL296DF045XE36B 7626919
14ACXS036-230A TXV 33,600 15.00 12.20 CR33-30/36B EL296DF045XV36B 7626924
14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL296DF070XE48B 7626922
14ACXS036-230A TXV 33,600 14.50 12.20 CR33-30/36B EL296DF070XV48B 7626927
14ACXS036-230A TXV 33,800 15.10 12.50 CR33-30/36B SL280DF090V48B 7626913
14ACXS036-230A TXV 33,800 15.00 12.50 CR33-30/36B SLP98DF070XV36B 7626930
14ACXS036-230A TXV 33,400 14.25 11.50 CR33-30/36B 7782777
14ACXS036-230A TXV 33,800 15.50 12.50 CR33-30/36C EL180DF110E60C 7626938
14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL195DF090XE48C 7626940
14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL195DF110XE60C 7782781
14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL296DF090XE48C 7626943
14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C EL296DF090XV60C 7782783
14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL296DF110XE60C 7626946
14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C EL296DF110XV60C 7782784
14ACXS036-230A TXV 34,000 15.50 12.50 CR33-30/36C SL280DF110V60C 7626935
14ACXS036-230A TXV 33,800 15.10 12.50 CR33-30/36C SLP98DF090XV36C 7782782
14ACXS036-230A TXV 33,800 15.10 12.50 CR33-30/36C SLP98DF090XV48C 7626949
14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C SLP98DF090XV60C 7626952
14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C SLP98DF110XV60C 7626955
14ACXS036-230A TXV 33,400 14.25 11.50 CR33-30/36C 7626932
14ACXS036-230A TXV 34,200 15.00 12.50 CR33-48B EL180DF070E36B 7783197
14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48B EL180DF090E48B 7628444
14ACXS036-230A TXV 34,000 15.10 12.50 CR33-48B EL195DF045XE36B 7783198
14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B EL195DF070XE48B 7783199
14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B EL296DF045XE36B 7628447
14ACXS036-230A TXV 34,200 15.10 12.50 CR33-48B EL296DF045XV36B 7783200
14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B EL296DF070XE48B 7628450
14ACXS036-230A TXV 34,200 15.10 12.50 CR33-48B EL296DF070XV48B 7628453
14ACXS036-230A TXV 34,600 15.50 12.50 CR33-48B SL280DF090V48B 7628441
14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B SLP98DF070XV36B 7783201
14ACXS036-230A TXV 33,800 14.25 12.00 CR33-48B 7783196
14ACXS036-230A TXV 34,400 16.00 13.00 CR33-48C EL180DF110E60C 7783203
14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48C EL195DF090XE48C 7628462
14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48C EL195DF110XE60C 7628465
14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48C EL296DF090XE48C 7783204
14ACXS036-230A TXV 34,600 15.50 12.50 CR33-48C EL296DF090XV60C 7628471
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.