A I R H A N D L E R S
B SERIES
R-410A or R-22 - Multi-Position - 50HZ/60HZ (Export Only)
Bulletin No. 490137
September 2009
E N G I N E E R I N G D ATA
3.5 to 17.6 kW (1 to 5 Tons)
Optional Electric Heat - 2.5 to 25 kW
Optional Hot Water Heat -
2.6 to 36.3 kW (9,000 to 124,000 Btuh)
CABINET
Enhanced grommets - secure & tight.
Multi-position available from factory and eld
convertible.
Side return right- or left-hand capable on 12 to 30 and
36 size models.
All air handlers are basiloid packaged with bar coding
and full description on label.
Magnetic lter rack door makes for easy lter
replacement and a tight seal for less air leakage.
Fiberglass air lter comes with every air handler and
lter racks accepts readily available size lters.
Rigid beige painted cabinets constructed of heavy
gauge steel to prevent corrosion and are lined with high
quality
9.5 mm (5/8 in.) foil faced insulation to prevent
sweating.
EVAPORATOR COIL
Patented lanced n design and internally enhanced
copper tubing.
Suitable for use with R-22 and R-410A.
Dual 19 mm (3/4 in.) FPT left and right condensate
drain connections.
Drain pans are molded of corrosion proof high
temperature engineering polymer.
Coils are air pressure tested at 72 kPa (500 PSI),
pressure tested with Helium, sealed and then charged
with dry air.
Florator, non-bleed A/C or HP TXV’s available factory
installed. Screw-on TXV’s also available for eld
installation.
HOT WATER HEAT
Suitable for potable water systems.
Hot Water Heat Kits available both factory and eld
installed.
Easy to replace hot water coil. Remove one screw and
slide out.
Optional factory installed circulating pump fully encased
in cabinet.
Purge valve on hot water coil allows for manual release
of any air trapped in coil during installation or servicing.
Water connections 7/8 in. ODF (for 3/4 in. water pipe)
on 12 to 30, and 36 size models and 1-1/8 in. ODF (for
1 in. water pipe) on 31, and 37 - 60 size models.
Control board comes standard factory installed on all
Air Handlers and includes the following features:
Features are compatible with both factory and eld
installed circulating pumps.
1. Pump timer activates pump for 1 minute every 6
hours eliminating stagnant water in hot water coil.
2. 24 VAC isolation valve control-allows for zoning
control.
3. Auxiliary contacts for water heater or boiler
activation.
4. Freeze protection- standard factory installed,
activates at 4°C (40°F) and deactivates at 21°C (70°F).
5. Thermostat connections.
6. Time delay for blower activation:
• 60 seconds (tap in OFF position)
• 54°C (130°F) Aquastat (tap in ON position)
Note: Aquastat tap only included if ordered
FEATURES