Page 1
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
WARNING
Electric Shock Hazard.
Can cause injury or death.
Foil-faced insulation has conductive
characteristics similar to metal. Be sure there
are no electrical connections within 1/2ʺ
of the insulation. If the foil-faced insulation
comes in contact with electrical voltage, the
foil could provide a path for current to pass
through to the outer metal cabinet. While
the current produced may not be enough to
trip existing electrical safety devices (e.g.,
fuses or circuit breakers), the current can be
enough to cause an electrical shock hazard
that could cause personal injury or death.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
INSTALLATION
INSTRUCTIONS
ELECTRIC HEAT SECTIONS
507805-01
12/2017
ECB38 Series Units
Shipping and Packing List
Package 1 of 1 contains:
1 – Assembled electric heat section
1 – Bag assembly containing the following:
Screws - 6 each
Wiring diagram - 1 each
Circuit breaker cover - 1 each
2 – Adhesive-backed foam seals
Check equipment for shipping damage; if found, immedi-
ately contact the last carrier.
WARNING
Electric shock hazard! - Disconnect all power
supplies before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
ELECTRIC HEAT WILL NOT OPERATE
IF IT IS NOT CONFIGURED (SET UP)
THROUGH THE AIR HANDLER
CONTROL (AHC).
SEE CONFIGURATION PROCEDURE,
FIGURE 12 ON PAGE 9.
IMPORTANT INFORMATION FOR INSTALLER
H
H
CONFIGURE ELECTRIC HEAT
ECB38
®
OR iComfort
®
S30 INSTALLER
SETUP, ELECTRIC HEAT MUST BE MANUALLY CONFIGURED.
Question and Answer IconNeed help?

Do you have a question about the Lennox ECB38-15CB and is the answer not in the manual?

Lennox ECB38-15CB Specifications

General IconGeneral
Product TypeHeat Pump
SEER RatingUp to 15
HSPF Rating8.5
Refrigerant TypeR-410A
Voltage (V)208/230
Phase1

Summary

INSTALLATION INSTRUCTIONS ECB38 Series Units

IMPORTANT INFORMATION FOR INSTALLER

CONFIGURE ELECTRIC HEAT

Manual configuration of electric heat is required before installer setup.

Electric Heat Sections

General Information

General guidelines, local codes, safety, and standards for installation.

Heat Section Installation

Steps for installing the electric heat section, including power shutoff and panel removal.

Circuit Breaker Installation

Circuit Breaker Cover Installation

Instructions for installing the circuit breaker cover for unconditioned spaces.

Discharge Air Temperature Sensor

Details on the discharge air sensor required for EVENHEAT operation.

Electrical Connections

AIR HANDLER CONTROL 9-PIN CONNECTOR

Wiring connections between the air handler and ECB38 heat section.

Unit Start-Up

Blower Speed and Configuration

Setting blower speed and configuring unit modes (Standard/EVENHEAT).

Panel and Plate Installation

Installing circuit breaker seals, patch plates, and covers.

Final Settings

Setting the thermostat after installation.

Configuring Unit

Air Handler Control Checkout

Checkout procedure for the Air Handler Control unit.

Configuring Unit Size Codes

Heat Mode Selection

ConfiguringDetecting Electric Heat Sections

Manual configuration to detect the number of electric heat sections installed.

EVENHEAT Operation

Electric Heat Wiring Diagram Cross Reference

Related product manuals