EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 4
COMPRESSOR
Scroll Compressor
Compressor features high
operation.
Compressor consists of two
together to generate a series of
crescent shaped gas pockets
During compression, one scroll
remains stationary while the other
Gas is drawn into the outer pocket, the pocket is sealed
as the scroll rotates.
pockets is simultaneously reduced.
When the pocket reaches the center, gas is now at high
pressure and is forced out of a port located in the center
simultaneously resulting in a smooth continuous
compression cycle.
Scroll compressor is tolerant to the effects of slugging
and contaminants. If this occurs, scrolls separate,
center and discharged.
Low gas pulses during compression reduces
Compressor motor is internally protected from
Compressor is installed in the unit on specially
Compressor Crankcase Heater (060 Models)
Protects against refrigerant migration that can occur
Factory Installed.
Compressor Sound Dampening System
dampening.
All open edges are sealed with a one-inch wide hook
and loop fastening tape.
F
Optional Accessories
Compressor Crankcase Heater (018 thru 048
models)
Protects against refrigerant migration that can occur
Compressor Hard Start Kit
Single-phase units are equipped with a PSC
need a potential relay and start capacitor.
required to increase the compressor starting torque.
Compressor Low Ambient Cut-Off Switch
compressor operation when outdoor temperature is
CONTROLS
Optional Accessories
Indoor Blower Off Delay Relay
cycle.
See AHRI System Matches for usage.
Low Ambient Kit
Air conditioners operate satisfactorily down to 45°F
outdoor air temperature without any additional controls.
unit operation down to 30°F.
operation conditions
Thermostat
Thermostat not furnished with unit. See Thermostat
Compressor Timed-Off Control
for suction and discharge pressure to equalize.
Permits compressor start-up in an unloaded condition.
compressor shut-off and start-up.
FEATURES