EasyManua.ls Logo

Lennox Elite XC13 - User Manual

Lennox Elite XC13
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
03/10 506120−01
*2P0310* *P506120-01*
Page 1
2010 Lennox Industries Inc.
Dallas, Texas, USA
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause personal injury,
loss of life, or damage to property.
Installation and service must be performed by a
licensed professional installer (or equivalent) or a
service agency.
CAUTION
Physical contact with metal edges and corners
while applying excessive force or rapid motion can
result in personal injury. Be aware of, and use
caution when working near these areas during
installation or while servicing this equipment.
IMPORTANT
The Clean Air Act of 1990 bans the intentional
venting of refrigerant (CFCs, HCFCs and HFCs) as
of July 1, 1992. Approved methods of recovery,
recycling or reclaiming must be followed. Fines
and/or incarceration may be levied for
noncompliance.
IMPORTANT
This unit must be matched with an indoor coil as
specified in Lennox XC13 Engineering Handbook.
Coils previously charged with HCFC−22 must be
flushed.
INSTALLATION
INSTRUCTIONS
Elite
®
Series XC13 Units
AIR CONDITIONER
506120−01
03/10
Supersedes 07/09
Table of Contents
Shipping and Packing List 1. . . . . . . . . . . . . . . . . . . . . .
XC13 Air Conditioner Units 1. . . . . . . . . . . . . . . . . . . . .
Unit Dimensions 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Information 3. . . . . . . . . . . . . . . . . . . . . . . . . . .
Recovering Refrigerant from Existing System 4. . . . .
Removing Existing Outdoor Unit 5. . . . . . . . . . . . . . . . .
New Outdoor Unit Installation 5. . . . . . . . . . . . . . . . . . .
Removing and Installing SmartHingePanels 7. . . . .
New or Replacement Line Set 8. . . . . . . . . . . . . . . . . . .
Brazing Connections 10. . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing Indoor Unit Metering Device 11. . . . . . . . . . .
Flushing the System 12. . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigerant Metering Device Kits 13. . . . . . . . . . . . . . . .
Installing New Indoor Unit Metering Device 13. . . . . . . .
Leak Testing the System 15. . . . . . . . . . . . . . . . . . . . . . .
Evacuating the System 16. . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections 18. . . . . . . . . . . . . . . . . . . . . . . . .
Servicing Outdoor Unit Delivered Void of Charge 20. . .
Start−Up Procedure 21. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing Charge 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Charging System 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Operation 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Homeowner Information 27. . . . . . . . . . . . . . . . . . . . . . . .
Start−Up and Performance Checklist 28. . . . . . . . . . . . .
Shipping and Packing List
Check the unit for shipping damage and listed times below
are intact. If damaged, or if parts are missing, immediately
contact the last shipping carrier.
1  Assembled outdoor unit.
1  Refrigerant flow control (RFC) kit (Fixed Orifice)
XC13 Air Conditioner Units
The XC13 Air Conditioners, which will also be referred to in
this instruction as the outdoor unit, uses HFC−410A
refrigerant. This outdoor unit must be installed with a
matching indoor unit and line set as outlined in the Lennox
XC13 Engineering Handbook.