AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-036-230 TXV 35,400 14.50 11.00 CH33-43C 3068647
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-045 3068738
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-070 3068739
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-071 3068741
XC16-036-230 TXV 35,800 16.00 11.70 CH33-44/48 SL280UH090V36B 3933005
XC16-036-230 TXV 35,600 15.70 11.70 CH33-44/48 SL280UH090V48B 3933006
XC16-036-230 TXV 35,600 15.70 11.70 CH33-44/48 SL280UH090XV48B 4038680
XC16-036-230 TXV 35,600 15.70 11.50 CH33-44/48 SLP98UH070V36B 4020655
XC16-036-230 TXV 35,200 14.20 11.00 CH33-44/48 3068648
XC16-036-230 TXV 36,200 16.50 12.00 CH33-48 SL280UH090V60C 3933007
XC16-036-230 TXV 36,200 16.50 12.00 CH33-48 SL280UH090XV60C 4235453
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SL280UH110V60C 3933008
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SL280UH110XV60C 4040513
XC16-036-230 TXV 35,800 16.20 11.70 CH33-48 SLP98UH090V36C 4020656
XC16-036-230 TXV 36,000 16.50 11.70 CH33-48 SLP98UH090V48C 4020657
XC16-036-230 TXV 36,200 16.20 11.70 CH33-48 SLP98UH090V60C 4020658
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SLP98UH110V60C 4020659
XC16-036-230 TXV 35,200 14.20 11.00 CH33-48 3068649
XC16-036-230 TXV 35,600 16.20 11.70 CH33-48C G61MPV-36C-090 3068744
XC16-036-230 TXV 34,400 15.20 11.00 CR33-30/36 G61MPV-36B-045 3068708
XC16-036-230 TXV 34,400 15.50 11.20 CR33-30/36 G61MPV-36B-070 3068709
XC16-036-230 TXV 34,200 15.50 11.00 CR33-30/36 G61MPV-36B-071 3068711
XC16-036-230 TXV 34,600 15.50 11.50 CR33-30/36 G61MPV-36C-090 3068712
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 G61MPV-60C-090 4207541
XC16-036-230 TXV 34,600 15.50 11.20 CR33-30/36 SL280DF070V36A 3933009
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SL280DF090V48B 3933010
XC16-036-230 TXV 35,200 16.00 11.70 CR33-30/36 SL280DF090V60C 3933011
XC16-036-230 TXV 35,000 16.00 11.70 CR33-30/36 SL280DF110V60C 3933012
XC16-036-230 TXV 34,400 15.50 11.20 CR33-30/36 SLP98DF070V36B 4020660
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 SLP98DF090V36C 4020661
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 SLP98DF090V48C 4020662
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SLP98DF090V60C 4020663
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SLP98DF110V60C 4020664
XC16-036-230 TXV 34,200 14.00 10.70 CR33-30/36 3068638
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SL280DF090V48B 3933013
XC16-036-230 TXV 35,200 15.70 11.70 CR33-48 SL280DF090V60C 3933014
XC16-036-230 TXV 34,800 16.00 11.70 CR33-48 SL280DF110V60C 3933015
XC16-036-230 TXV 34,400 15.70 11.50 CR33-48 SLP98DF070V36B 4020665
XC16-036-230 TXV 34,600 15.70 11.50 CR33-48 SLP98DF090V36C 4020666
XC16-036-230 TXV 34,800 15.70 11.70 CR33-48 SLP98DF090V48C 4020667
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SLP98DF090V60C 4020668
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SLP98DF110V60C 4020669
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.