XC16 - 2 to 5 Ton Air Conditioner / Page 15
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC16-036-230 TXV 35,400 14.50 11.00 CH33-43C 3068647
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-045 3068738
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-070 3068739
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-071 3068741
XC16-036-230 TXV 35,800 16.00 11.70 CH33-44/48 SL280UH090V36B 3933005
XC16-036-230 TXV 35,600 15.70 11.70 CH33-44/48 SL280UH090V48B 3933006
XC16-036-230 TXV 35,600 15.70 11.70 CH33-44/48 SL280UH090XV48B 4038680
XC16-036-230 TXV 35,600 15.70 11.50 CH33-44/48 SLP98UH070V36B 4020655
XC16-036-230 TXV 35,200 14.20 11.00 CH33-44/48 3068648
XC16-036-230 TXV 36,200 16.50 12.00 CH33-48 SL280UH090V60C 3933007
XC16-036-230 TXV 36,200 16.50 12.00 CH33-48 SL280UH090XV60C 4235453
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SL280UH110V60C 3933008
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SL280UH110XV60C 4040513
XC16-036-230 TXV 35,800 16.20 11.70 CH33-48 SLP98UH090V36C 4020656
XC16-036-230 TXV 36,000 16.50 11.70 CH33-48 SLP98UH090V48C 4020657
XC16-036-230 TXV 36,200 16.20 11.70 CH33-48 SLP98UH090V60C 4020658
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SLP98UH110V60C 4020659
XC16-036-230 TXV 35,200 14.20 11.00 CH33-48 3068649
XC16-036-230 TXV 35,600 16.20 11.70 CH33-48C G61MPV-36C-090 3068744
XC16-036-230 TXV 34,400 15.20 11.00 CR33-30/36 G61MPV-36B-045 3068708
XC16-036-230 TXV 34,400 15.50 11.20 CR33-30/36 G61MPV-36B-070 3068709
XC16-036-230 TXV 34,200 15.50 11.00 CR33-30/36 G61MPV-36B-071 3068711
XC16-036-230 TXV 34,600 15.50 11.50 CR33-30/36 G61MPV-36C-090 3068712
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 G61MPV-60C-090 4207541
XC16-036-230 TXV 34,600 15.50 11.20 CR33-30/36 SL280DF070V36A 3933009
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SL280DF090V48B 3933010
XC16-036-230 TXV 35,200 16.00 11.70 CR33-30/36 SL280DF090V60C 3933011
XC16-036-230 TXV 35,000 16.00 11.70 CR33-30/36 SL280DF110V60C 3933012
XC16-036-230 TXV 34,400 15.50 11.20 CR33-30/36 SLP98DF070V36B 4020660
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 SLP98DF090V36C 4020661
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 SLP98DF090V48C 4020662
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SLP98DF090V60C 4020663
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SLP98DF110V60C 4020664
XC16-036-230 TXV 34,200 14.00 10.70 CR33-30/36 3068638
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SL280DF090V48B 3933013
XC16-036-230 TXV 35,200 15.70 11.70 CR33-48 SL280DF090V60C 3933014
XC16-036-230 TXV 34,800 16.00 11.70 CR33-48 SL280DF110V60C 3933015
XC16-036-230 TXV 34,400 15.70 11.50 CR33-48 SLP98DF070V36B 4020665
XC16-036-230 TXV 34,600 15.70 11.50 CR33-48 SLP98DF090V36C 4020666
XC16-036-230 TXV 34,800 15.70 11.70 CR33-48 SLP98DF090V48C 4020667
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SLP98DF090V60C 4020668
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SLP98DF110V60C 4020669
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.