EasyManuals Logo

Lennox FLEXY FC 050 Series User Manual

Lennox FLEXY FC 050 Series
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
IOM / ROOF-TOP FLEXY™ Series - Page 39
USING THE KP02 MAINTENANCE CONTROL DISPLAUSING THE KP02 MAINTENANCE CONTROL DISPLA
USING THE KP02 MAINTENANCE CONTROL DISPLAUSING THE KP02 MAINTENANCE CONTROL DISPLA
USING THE KP02 MAINTENANCE CONTROL DISPLA
YY
YY
Y
82 Battery Temperature, setpoint, Authorised defrosting -10.0 -3.0 3.0
83 Coefficient, Icing time 0 3 12
84 Number, Condensor restart 1 3 8
85 Low Temperature, setpoint, GOLD heat exchanger 4.0 5.0 20.0
86 High Temperature, setpoint, GOLD heat exchanger 20.0 45.0 46.0
87 Outside Temperature, setpoint, 100% Elec. res. discharge -20.0 10.0 30.0
88 Sensing setpoint, Air flow cutout 0.0 0.2 5.0
89 Sensing setpoint, Clogged filters 0.0 2.5 5.0
90 Sensing setpoint, Missing filters 0.0 0.5 5.0
91 Unit type 0 0 65535
92 On = ‘L’ Series, Off = ‘F’ Series Off # On
93 On = Advanced Control Pack Option Fitted Off # On
94 All setpoint values forced to factory values Off Off On
95 Test stages 0 0 65535
VARIABLE LIST
1st Level
0 Error code
1 Temperature, Room
2 Relative humidity (%), Room
3 Temperature, Outside Air
4 Relative humidity (%), Outside, Air
5 Temperature, Supply Air
6 Temperature, chilled water battery
7 Temperature, Compressor, no. 1
8 Temperature, Compressor, no. 2
9 Temperature, Compressor, no. 3
10 Temperature, Compressor, no. 4
11 Temperature, Condensor, no. 1
12 Temperature, Condensor, no. 2
13 Temperature, Condensor, no. 3
14 Temperature, Condensor, no. 4
15 Temperature, GOLD condensor, Water outlet
16 Pressure, Air flow
17 Air quality sensor, CO² (ppm)
18 Pressure, Compressor, no. 1
19 Pressure, Compressor, no. 2
20 Pressure, Compressor, no. 3
21 Pressure, Compressor, no. 4
22 Hard contact, Remote control, Unit Off
23 Hard contact, Remote control, forced occupied mode
24 Hard contact, Remote control, forced unoccupied mode
25 Hard contact, Remote control, 50% Forced load limit
26 Hard contact, Remote control, Forced heating cancellation
27 Hard contact, Remote control, Forced cooling cancellation
28 Hard contact, Remote control, Low ventilation speed
29 Auxiliary contact, blower fan

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox FLEXY FC 050 Series and is the answer not in the manual?

Lennox FLEXY FC 050 Series Specifications

General IconGeneral
BrandLennox
ModelFLEXY FC 050 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals