G61MPV / Page 27
BLOWER DATA
G61MPV−60C−110 BLOWER PERFORMANCE (less filter)
Single Side Return Air − Air volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. cleanable air filter in
order to maintain proper air velocity across the filter.
0 through 0.80 in. w.g. External Static Pressure Range
"
Speed Switch Positions
Switch
Second Stage HEAT" Speed − cfm Second Stage COOL" Speed − cfm
Positions
1
1
2 3 4 1 2 3
1
4
+ 1485 1675 1870 2080 1585 1700 1905 2135
1
NORM 1350 1525 1725 1895 1435 1535 1740 1930
1175 1335 1505 1670 1280 1385 1570 1755
ADJUST"
First Stage HEAT" Speed − cfm First Stage COOL" Speed − cfm
Switch
Positions
1
1
2 3 4 1 2 3
1
4
+ 1325 1505 1695 1870 935 1025 1155 1285
1
NORM 1195 1365 1550 1720 840 915 1050 1175
1080 1205 1365 1530 750 800 925 1050
1
Factory default jumper setting.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage
HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm.
Lennox Harmony III Zone Control Applications − Minimum blower speed is 463 cfm.
G61MPV−60C−110 BLOWER MOTOR WATTS
Motor Watts @ Various External Static Pressures − in. wg.
Jumper Speed
First Stage Second Stage
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
+" (Plus) SETTING (Adjust" Jumper at +" Setting)
HEAT"
Tap 1
155 185 220 255 285 320 350 380 410 205 240 280 320 355 390 420 450 480
Speed
Tap 2
215
255 300 345 370 395 430 465 500 320 350 380 410 455 495 530 565 595
Tap 3
335
375 415 455 490 530 570 605 645 445 475 510 545 590 630 670 710 750
Tap 4
450
490 535 580 615 645 690 730 775 580 625 680 735 770 810 850 890 930
COOL"
Tap 1
70 90 110 130 150 165 185 210 230 255 295 345 390 430 470 510 545 580
Speed
Tap 2
85
105 125 150 170 190 215 235 255 340 375 415 455 490 525 570 615 660
Tap 3
115
135 160 185 210 230 255 285 310 455 500 555 610 650 695 750 800 850
Tap 4
155
175 195 220 250 285 310 335 360 650 710 770 835 880 920 960 995 1035
NORM" (Normal) SETTING (Adjust" Jumper at NORM" Setting)
HEAT"
Tap 1
140 160 185 210 235 265 285 310 330 155 185 220 250 285 320 350 380 410
Speed
Tap 2
170
200 235 270 305 340 370 400 430 220 260 300 345 370 395 430 465 500
Tap 3
250
290 330 370 400 430 465 505 540 355 385 415 450 485 520 555 595 630
Tap 4
360
395 430 465 510 550 580 605 635 460 490 525 560 605 645 685 730 770
COOL"
Tap 1
60 75 90 110 125 145 165 185 205 195 230 270 305 345 380 415 455 490
Speed
Tap 2
70
85 105 125 140 160 180 200 220 225 265 315 360 400 440 475 515 555
Tap 3
95
110 130 150 175 200 225 245 265 365 400 445 485 525 565 610 650 690
Tap 4
115
135 165 190 215 235 260 285 310 495 535 580 625 675 725 770 815 860
−" (Minus) SETTING (Adjust" Jumper at −" Setting)
HEAT"
Tap 1
105 125 150 175 195 215 240 265 290 135 155 180 205 225 245 275 300 330
Speed
Tap 2
145
165 190 210 240 265 290 315 340 170 195 225 255 290 325 355 385 410
Tap 3
175
200 235 265 300 335 370 400 430 230 260 295 335 370 405 440 475 510
Tap 4
240
275 320 360 390 420 450 485 515 325 365 410 455 490 520 550 575 600
COOL"
Tap 1
45 60 80 100 110 125 140 155 170 155 180 205 235 270 305 340 370 400
Speed
Tap 2
50
65 85 100 120 135 155 175 195 170 200 240 275 315 355 390 420 450
Tap 3
75
90 105 120 140 160 185 210 235 250 290 330 375 410 445 485 525 570
Tap 4
95 110 135 155 175 200 225 250 270 365 405 450 490 535 575 615 655 690