EasyManua.ls Logo

Lennox HP29-261 User Manual

Lennox HP29-261
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
© 1997 Lennox Industries Inc.
Litho U.S.A.
Corp. 9709−L5
Revised 5−2000
HP29
Service Literature
HP29 SERIES UNITS
The HP29 is a residential split-system heat pump. Outdoor coil
size, circuiting and air volume result in a minimum SEER rating
of 10.0. All HP29 units are designed for use with thermal
expansion valves.
Some HP29 units (−211 through −650, −018 and −024) utilize a
reciprocating compressor. These models are furnished with
crankcase heaters. The heater prevents liquid from
accumulating in the compressor. All compressors are
hermetically sealed for trouble-free operation and long service
life. Reciprocating compressor components are
spring-mounted within the sealed housing. A built-in limit
protects the compressor from excessive current and
temperatures. Other HP29 units (−030 through −060) utilize a
scroll compressor. The scroll operates like a standard
heatpump, but is unique in the way that it compresses
refrigerant.
This manual is divided into sections which discuss major
components, refrigerant system, charging procedures,
maintenance, and operation sequence .
All specifications in this manual are subject to change.
SPECIFICATIONS
Model No. HP29-211 HP29-261 HP29-311
Ntf ft(
2
)
Outer coil 11.41 (1.06) 11.41 (1.06) 13.31 (1.24)
Outdoor
Net face area - sq. ft. (m
2
)
Inner coil - - - - - - - - - - - -
Outdoor
Coil
Tube diameter in. (mm) & no. of rows 5/16 (7.9)  1 5/16 (7.9)  1 5/16 (7.9)  1
Coil
Fins per inch (m) 22 (866) 22 (866) 22 (866)
Diameter  in. (mm) & no. of blades 18 (457)  3 18 (457)  3 18 (457)  4
Outdoor
Motor hp (W) 1/6 (124) 1/6 (124) 1/6 (124)
Outdoor
Coil
F
Cfm (L/s) 2400 (1135) 2400 (1135) 2500 (1180)
Coil
Fan
Rpm 1105 1105 1100
Watts 180 180 200
*Refrigerant charge furnished (HCFC-22) 4 lbs. 5 oz. (1.96 kg) 4 lbs. 4 oz. (1.92 kg) 4 lbs. 15 oz. (2.24 kg)
Liquid line  in. (mm) o.d. connection (sweat) **3/8 to 5/16 (8) **3/8 to 5/16 (8) **3/8 to 5/16 (8)
Vapor line  in. (mm) o.d. connection (sweat) 5/8 (15.9) 5/8 (15.9) 3/4 (19.1)
Shipping weight  lbs. (kg) 1 package 152 (69) 152 (69) 164 (74)
*Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.
**5/16 to 3/8 reducer coupling supplied with unit.
SPECIFICATIONS
Model No. HP29-411/HP29-41 HP29-461/HP29-463 HP29-511/HP29-513 HP29-651/HP29-653
Net face area sq ft (m
2
)
Outer coil 15.21 (1.41) 15.21 (1.41) 15.21 (1.41) 15.21 (1.41)
Outdoor
Net face area - sq. ft. (m
2
)
Inner coil - - - - 5.44 (0.51) 5.44 (0.51) 14.50 (13.5)
Outdoor
Coil
Tube diameter in. (mm) & no. of rows 5/16 (7.9)  1 5/16 (7.9)  1.37 5/16 (7.9)  1.37 5/16 (7.9)  2
Fins per inch (m) 22 (866) 22 (866) 22 (866) 22 (866)
Diameter  in. (mm) & no. of blades 18 (457)  4 18 (457)  4 18 (457)  4 18 (457)  4
Outdoor
Motor hp (W) 1/6 (124) 1/6 (124) 1/3 (249) 1/3 (249)
Outdoor
Coil
F
Cfm (L/s) 2520 (1190) 2500 (1180) 2950 (1390) 2930 (1385)
Coil
Fan
Rpm 1100 1100 1100 1100
Watts 200 200 310 310
*Refrigerant charge furnished (HCFC-22) 6 lbs. 3 oz. (2.81 kg) 7 lbs. 13 oz. (3.54 kg) 7 lbs. 1 oz. (3.20 kg) 9 lbs. 0 oz. (4.08 kg)
Liquid line  in. (mm) o.d. connection (sweat) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5)
Vapor line  in. (mm) o.d. connection (sweat) 3/4 (19.1) 7/8 (22.2) 7/8 (22.2) 1-1/8 (28.6)
Shipping weight  lbs. (kg) 1 package 174 (79) 199 (90) 206 (93) 221 (100)
*Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.
Библиотека СОК
Question and Answer IconNeed help?

Do you have a question about the Lennox HP29-261 and is the answer not in the manual?

Lennox HP29-261 Specifications

General IconGeneral
BrandLennox
ModelHP29-261
CategoryHeat Pump
LanguageEnglish

Summary

UNIT INFORMATION AND SPECIFICATIONS

HP29 SERIES UNITS

Introduction to the HP29 series heat pumps.

SPECIFICATIONS

Detailed technical specifications for various models.

UNIT INFORMATION AND SPECIFICATIONS (CONTINUED)

ELECTRICAL DATA

Electrical parameters for HP29 models.

UNIT COMPONENTS

UNIT COMPONENTS (CONTINUED)

DEFROST SYSTEM FEATURES (CONTINUED)

COMPRESSOR INFORMATION

REFRIGERANT SYSTEM COMPONENTS

PLUMBING AND LINE SETS

CHARGING AND SYSTEM PREPARATION

CHARGING AND SYSTEM PREPARATION (CONTINUED)

REFRIGERANT LINE INSTALLATION AND NOISE

WIRING DIAGRAMS

WIRING DIAGRAMS (CONTINUED)

Single-Phase Scroll Compressor Wiring

Final view of scroll compressor wiring.

OPERATING SEQUENCE

Single-Phase Operation Sequence

Detailed steps for cooling and heating.

OPERATING SEQUENCE (CONTINUED)

Three-Phase Compressor Wiring

Another view of three-phase wiring.

Three-Phase Operation Sequence

Detailed steps for three-phase unit operation.