HP29
Service Literature
HP29 SERIES UNITS
The HP29 is a residential split-system heat pump. Outdoor coil
size, circuiting and air volume result in a minimum SEER rating
of 10.0. All HP29 units are designed for use with thermal
expansion valves.
Some HP29 units (−211 through −650, −018 and −024) utilize a
reciprocating compressor. These models are furnished with
crankcase heaters. The heater prevents liquid from
accumulating in the compressor. All compressors are
hermetically sealed for trouble-free operation and long service
life. Reciprocating compressor components are
spring-mounted within the sealed housing. A built-in limit
protects the compressor from excessive current and
temperatures. Other HP29 units (−030 through −060) utilize a
scroll compressor. The scroll operates like a standard
heatpump, but is unique in the way that it compresses
refrigerant.
This manual is divided into sections which discuss major
components, refrigerant system, charging procedures,
maintenance, and operation sequence .
All specifications in this manual are subject to change.
SPECIFICATIONS
Model No. HP29-211 HP29-261 HP29-311
Ntf ft(
2
)
Outer coil 11.41 (1.06) 11.41 (1.06) 13.31 (1.24)
Outdoor
Net face area - sq. ft. (m
2
)
Inner coil - - - - - - - - - - - -
Outdoor
Coil
Tube diameter in. (mm) & no. of rows 5/16 (7.9)  1 5/16 (7.9)  1 5/16 (7.9)  1
Coil
Fins per inch (m) 22 (866) 22 (866) 22 (866)
Diameter  in. (mm) & no. of blades 18 (457)  3 18 (457)  3 18 (457)  4
Outdoor
Motor hp (W) 1/6 (124) 1/6 (124) 1/6 (124)
Outdoor
Coil
F
Cfm (L/s) 2400 (1135) 2400 (1135) 2500 (1180)
Coil
Fan
Rpm 1105 1105 1100
Watts 180 180 200
*Refrigerant charge furnished (HCFC-22) 4 lbs. 5 oz. (1.96 kg) 4 lbs. 4 oz. (1.92 kg) 4 lbs. 15 oz. (2.24 kg)
Liquid line  in. (mm) o.d. connection (sweat) **3/8 to 5/16 (8) **3/8 to 5/16 (8) **3/8 to 5/16 (8)
Vapor line  in. (mm) o.d. connection (sweat) 5/8 (15.9) 5/8 (15.9) 3/4 (19.1)
Shipping weight  lbs. (kg) 1 package 152 (69) 152 (69) 164 (74)
*Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.
**5/16 to 3/8 reducer coupling supplied with unit.
SPECIFICATIONS
Model No. HP29-411/HP29-41 HP29-461/HP29-463 HP29-511/HP29-513 HP29-651/HP29-653
Net face area sq ft (m
2
)
Outer coil 15.21 (1.41) 15.21 (1.41) 15.21 (1.41) 15.21 (1.41)
Outdoor
Net face area - sq. ft. (m
2
)
Inner coil - - - - 5.44 (0.51) 5.44 (0.51) 14.50 (13.5)
Outdoor
Coil
Tube diameter in. (mm) & no. of rows 5/16 (7.9)  1 5/16 (7.9)  1.37 5/16 (7.9)  1.37 5/16 (7.9)  2
Fins per inch (m) 22 (866) 22 (866) 22 (866) 22 (866)
Diameter  in. (mm) & no. of blades 18 (457)  4 18 (457)  4 18 (457)  4 18 (457)  4
Outdoor
Motor hp (W) 1/6 (124) 1/6 (124) 1/3 (249) 1/3 (249)
Outdoor
Coil
F
Cfm (L/s) 2520 (1190) 2500 (1180) 2950 (1390) 2930 (1385)
Coil
Fan
Rpm 1100 1100 1100 1100
Watts 200 200 310 310
*Refrigerant charge furnished (HCFC-22) 6 lbs. 3 oz. (2.81 kg) 7 lbs. 13 oz. (3.54 kg) 7 lbs. 1 oz. (3.20 kg) 9 lbs. 0 oz. (4.08 kg)
Liquid line  in. (mm) o.d. connection (sweat) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5)
Vapor line  in. (mm) o.d. connection (sweat) 3/4 (19.1) 7/8 (22.2) 7/8 (22.2) 1-1/8 (28.6)
Shipping weight  lbs. (kg) 1 package 174 (79) 199 (90) 206 (93) 221 (100)
*Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.
Библиотека СОК
Question and Answer IconNeed help?

Do you have a question about the Lennox HP29-024 and is the answer not in the manual?

Lennox HP29-024 Specifications

General IconGeneral
Cooling Capacity (BTU)24000
Refrigerant TypeR-410A
Number of Stages1
Voltage (V)208/230
Phase1
Unit Weight (lbs)220

Summary

HP29 Series Units

Specifications Overview

Detailed technical specifications for various HP29 models.

Electrical Data

Line Voltage Parameters

Electrical parameters for different HP29 models, including amps and power factor.

Unit Components

Control Box and Wiring

Details on the electrical control box and thermostat wiring identification.

Component Illustration

Illustration of major unit components like compressor and control box.

Unit Components Details

Transformer T5 Details

Description and function of the step-down transformer T5.

Dual Capacitor C12 Function

Explanation of dual capacitors for single-phase motors.

Unit Components Details Continued

Potential Relay K31 Operation

Role of the potential relay in starting single-phase reciprocating compressors.

Start Capacitor C7 Usage

Function and rating of the start capacitor for reciprocating compressors.

Run Capacitor C1 for Fan Motors

Capacitor rating for fan motors in three-phase units.

Outdoor Fan Relay K10 Function

Relay for energizing the outdoor fan motor.

Compressor Contactor K1 Role

Contactor for energizing the compressor.

Defrost System (Reciprocating)

Defrost Thermostat S6

Operation and settings of the defrost thermostat.

Defrost Control CMC1

Functions of the defrost control board, including timing and diagnostics.

Defrost System Features

Defrost Timing Pin Settings

Explanation of timing pin selections for defrost cycle initiation.

Pressure Switch Safety Circuit

How pressure switches interact with the defrost control safety circuit.

Diagnostic LED Interpretation

Interpretation of diagnostic LEDs for troubleshooting defrost control issues.

Defrost System (Post-2002)

Defrost Thermostat Operation

Operation of the defrost thermostat for newer units.

Defrost Control Board Functions

Functions of the defrost control board in newer systems.

Defrost Timing Adjustments

Timing adjustments for the defrost cycle in newer units.

Defrost System Options

Optional Unit Pressure Switch Circuit

Pressure switch integration for optional units.

Optional Unit Diagnostic LEDs

LED indicators for troubleshooting optional units.

Time-Delay Relay Function

Function of the 5-minute time delay feature.

Ambient Thermistor & Service Light

Connections for ambient thermistor and service light.

Compressor Specifications and Rotation

Reciprocating Compressor Data

Specifications for reciprocating compressors used in HP29 units.

Scroll Compressor Data

Specifications for scroll compressors used in HP29 units.

Three-Phase Compressor Phasing

Procedures for ensuring correct three-phase compressor phasing.

Refrigerant System Components

Compressor Cover Details

Description of the compressor cover's construction and purpose.

Crankcase Heater Function

Function and ratings of the crankcase heater for reciprocating compressors.

Condenser Fan Motor Access

Access and specifications for the condenser fan motor.

Reversing Valve Operation

Function of the reversing valve for refrigerant flow control.

Service Valve Description

Description and accessibility of service valves for refrigerant handling.

Refrigerant System Valve Operation

Liquid Line Service Valve Use

Procedures for opening and closing liquid line service valves.

Refrigerant System Valve Operation Continued

Vapor Line Service Valve Use

Procedures for opening and closing vapor line service valves.

Ball Type Vapor Line Valve

Specifics on ball-type service valves for 5-ton units.

Plumbing and Line Sets

Line Set Specifications Table

Table showing line set lengths, liquid and vapor line diameters for models.

Refrigeration Components Diagram

Diagram of outdoor unit refrigerant components.

Charging Procedures

System Pumping Down

Procedure for pumping down the system before leak checking.

System Leak Testing

Steps for leak testing the system before evacuation.

System Evacuation Steps

Procedures for evacuating the refrigerant system to a specific vacuum level.

Charging Methods

Approach Method Charging (TXV)

Charging procedure for ambient temperatures 60°F or above.

Subcooling Method Charging (TXV)

Charging procedure for ambient temperatures below 60°F.

Charging Methods Continued

Normal Operating Pressures

Typical operating pressures for cooling and heating modes.

Refrigerant Line Noise Prevention

Vertical Line Set Installation

Procedures for installing line sets on vertical runs to prevent noise.

Refrigerant Line Noise Prevention Continued

Horizontal Line Set Installation

Procedures for installing line sets on horizontal runs to prevent noise.

Line Set Vertical-Horizontal Transition

Method for transitioning line sets between vertical and horizontal runs.

Outdoor Unit Placement Guidelines

Guidelines for placing the outdoor unit and line set.

Wiring Diagrams and Operation Sequence

Single-Phase Reciprocating Wiring

Wiring diagram for single-phase units with reciprocating compressors.

Single-Phase Reciprocating Wiring Details

Reciprocating Compressor Wiring Diagram

Detailed wiring diagram for HP29 single-phase reciprocating compressor units.

Single-Phase Reciprocating Wiring Diagrams

Reciprocating Compressor Wiring Details

Detailed wiring diagram for HP29 single-phase reciprocating compressor units.

Single-Phase Scroll Compressor Wiring

Scroll Compressor Wiring Diagram

Wiring diagram for single-phase units with scroll compressors.

Single-Phase Scroll Compressor Wiring Details

Scroll Compressor Wiring Details

Detailed wiring diagram for HP29 single-phase scroll compressor units.

Single-Phase Scroll Compressor Wiring Layout

Scroll Compressor Wiring Layout

Detailed wiring diagram for HP29 single-phase scroll compressor units.

Single-Phase Operating Sequence

HP29 P Voltage Sequence

Sequence of operation for HP29 'P' voltage units, covering cooling, heating, and defrost.

Three-Phase Compressor Wiring

Three-Phase Wiring Diagram (ReciprocatingScroll)

Wiring diagram for three-phase HP29 units with reciprocating or scroll compressors.

Three-Phase Wiring Diagram Details

Three-Phase Wiring Diagram Details

Wiring diagram for three-phase HP29 units with reciprocating or scroll compressors.

Three-Phase Operating Sequence

Three-Phase Operating Sequence

Sequence of operation for three-phase HP29 units, covering cooling, heating, and defrost.

Related product manuals