Page 1
© 1997 Lennox Industries Inc.
Litho U.S.A.
Corp. 9709−L5
Revised 5−2000
HP29
Service Literature
HP29 SERIES UNITS
The HP29 is a residential split-system heat pump. Outdoor coil
size, circuiting and air volume result in a minimum SEER rating
of 10.0. All HP29 units are designed for use with thermal
expansion valves.
Some HP29 units (−211 through −650, −018 and −024) utilize a
reciprocating compressor. These models are furnished with
crankcase heaters. The heater prevents liquid from
accumulating in the compressor. All compressors are
hermetically sealed for trouble-free operation and long service
life. Reciprocating compressor components are
spring-mounted within the sealed housing. A built-in limit
protects the compressor from excessive current and
temperatures. Other HP29 units (−030 through −060) utilize a
scroll compressor. The scroll operates like a standard
heatpump, but is unique in the way that it compresses
refrigerant.
This manual is divided into sections which discuss major
components, refrigerant system, charging procedures,
maintenance, and operation sequence .
All specifications in this manual are subject to change.
SPECIFICATIONS
Model No. HP29-211 HP29-261 HP29-311
Ntf ft(
2
)
Outer coil 11.41 (1.06) 11.41 (1.06) 13.31 (1.24)
Outdoor
Net face area - sq. ft. (m
2
)
Inner coil - - - - - - - - - - - -
Outdoor
Coil
Tube diameter in. (mm) & no. of rows 5/16 (7.9)  1 5/16 (7.9)  1 5/16 (7.9)  1
Coil
Fins per inch (m) 22 (866) 22 (866) 22 (866)
Diameter  in. (mm) & no. of blades 18 (457)  3 18 (457)  3 18 (457)  4
Outdoor
Motor hp (W) 1/6 (124) 1/6 (124) 1/6 (124)
Outdoor
Coil
F
Cfm (L/s) 2400 (1135) 2400 (1135) 2500 (1180)
Coil
Fan
Rpm 1105 1105 1100
Watts 180 180 200
*Refrigerant charge furnished (HCFC-22) 4 lbs. 5 oz. (1.96 kg) 4 lbs. 4 oz. (1.92 kg) 4 lbs. 15 oz. (2.24 kg)
Liquid line  in. (mm) o.d. connection (sweat) **3/8 to 5/16 (8) **3/8 to 5/16 (8) **3/8 to 5/16 (8)
Vapor line  in. (mm) o.d. connection (sweat) 5/8 (15.9) 5/8 (15.9) 3/4 (19.1)
Shipping weight  lbs. (kg) 1 package 152 (69) 152 (69) 164 (74)
*Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.
**5/16 to 3/8 reducer coupling supplied with unit.
SPECIFICATIONS
Model No. HP29-411/HP29-41 HP29-461/HP29-463 HP29-511/HP29-513 HP29-651/HP29-653
Net face area sq ft (m
2
)
Outer coil 15.21 (1.41) 15.21 (1.41) 15.21 (1.41) 15.21 (1.41)
Outdoor
Net face area - sq. ft. (m
2
)
Inner coil - - - - 5.44 (0.51) 5.44 (0.51) 14.50 (13.5)
Outdoor
Coil
Tube diameter in. (mm) & no. of rows 5/16 (7.9)  1 5/16 (7.9)  1.37 5/16 (7.9)  1.37 5/16 (7.9)  2
Fins per inch (m) 22 (866) 22 (866) 22 (866) 22 (866)
Diameter  in. (mm) & no. of blades 18 (457)  4 18 (457)  4 18 (457)  4 18 (457)  4
Outdoor
Motor hp (W) 1/6 (124) 1/6 (124) 1/3 (249) 1/3 (249)
Outdoor
Coil
F
Cfm (L/s) 2520 (1190) 2500 (1180) 2950 (1390) 2930 (1385)
Coil
Fan
Rpm 1100 1100 1100 1100
Watts 200 200 310 310
*Refrigerant charge furnished (HCFC-22) 6 lbs. 3 oz. (2.81 kg) 7 lbs. 13 oz. (3.54 kg) 7 lbs. 1 oz. (3.20 kg) 9 lbs. 0 oz. (4.08 kg)
Liquid line  in. (mm) o.d. connection (sweat) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5)
Vapor line  in. (mm) o.d. connection (sweat) 3/4 (19.1) 7/8 (22.2) 7/8 (22.2) 1-1/8 (28.6)
Shipping weight  lbs. (kg) 1 package 174 (79) 199 (90) 206 (93) 221 (100)
*Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.
Библиотека СОК
Question and Answer IconNeed help?

Do you have a question about the Lennox HP29-411 and is the answer not in the manual?

Lennox HP29-411 Specifications

General IconGeneral
BrandLennox
ModelHP29-411
CategoryHeat Pump
LanguageEnglish

Summary

UNIT INFORMATION AND SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Detailed technical data and model comparisons.

ELECTRICAL DATA

HP29-211 to HP29-653 Electrical Specs

Electrical specifications for single and three-phase units.

HP29-018 to HP29-060 Electrical Specs

Electrical specifications for single and three-phase units.

UNIT COMPONENTS - PART 1

DEFROST SYSTEM COMPONENTS

DEFROST SYSTEM OPERATION

COMPRESSOR SPECIFICATIONS

Reciprocating Compressors

Specifications for reciprocating compressors used in HP29 units.

Scroll Compressors

Specifications for scroll compressors used in HP29 units.

Three-Phase Compressor Rotation

Phasing requirements for three-phase scroll compressors.

REFRIGERANT SYSTEM

Liquid and Vapor Line Service Valves

Access points for testing, evacuating, and charging.

SERVICE VALVE OPERATION

PLUMBING AND REFRIGERANT LINES

CHARGING AND SYSTEM PREPARATION

Pumping Down System

Process for creating a vacuum before leak testing.

EXPANSION VALVE CHARGING METHODS

Approach Method

Charging procedure for ambient temperatures 60°F or above.

Subcooling Method

Charging procedure for ambient temperatures below 60°F.

MAINTENANCE

REFRIGERANT LINE NOISE MITIGATION

WIRING DIAGRAMS AND OPERATION SEQUENCE

Single-Phase Reciprocating Compressor Wiring

Wiring diagram for HP29 single-phase units.

Single-Phase Scroll Compressor Wiring

Wiring diagram for HP29 single-phase units.

Single-Phase Operating Sequence

Step-by-step operation for HP29 "P" voltage units.

Three-Phase Compressor Wiring

Wiring diagrams for HP29 three-phase units.

Three-Phase Operating Sequence

Step-by-step operation for HP29 "Y", "G", "J" voltage units.