2008 Lennox Industries Inc.
Dallas, Texas, USA
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause personal injury,
loss of life, or damage to property.
Installation and service must be performed by a
licensed professional installer (or equivalent) or a
service agency.
CAUTION
Physical contact with metal edges and corners
while applying excessive force or rapid motion can
result in personal injury. Be aware of, and use
caution when working near these areas during
installation or while servicing this equipment.
IMPORTANT
The Clean Air Act of 1990 bans the intentional
venting of refrigerant (CFCs, HCFCs AND HFCs) as
of July 1, 1992. Approved methods of recovery,
recycling or reclaiming must be followed. Fines
and/or incarceration may be levied for
noncompliance.
INSTALLATION
INSTRUCTIONS
Merit
®
Series13ACD Units
AIR CONDITIONER UNITS
505,366M
01/08
Supersedes 11/07
Table of Contents
Shipping and Packing List 1. . . . . . . . . . . . . . . . . . . . . .
13ACD Outdoor Unit 1. . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Dimensions 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Information 2. . . . . . . . . . . . . . . . . . . . . . . . . . .
Recovering Refrigerant from Existing System 4. . . . .
Removing Existing Outdoor Unit 5. . . . . . . . . . . . . . . . .
Positioning New Outdoor Unit 5. . . . . . . . . . . . . . . . . . .
New or Replacement Line Set 6. . . . . . . . . . . . . . . . . . .
Brazing Connections 8. . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing Indoor Unit Metering Device 9. . . . . . . . . . . .
Installing New Indoor Unit Metering Device 9. . . . . . . .
Testing for Leaks 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Evacuating the System 12. . . . . . . . . . . . . . . . . . . . . . . . .
Servicing Unit Delivered Void of Charge 13. . . . . . . . . . .
Electrical Connections 13. . . . . . . . . . . . . . . . . . . . . . . . .
Start−Up and Charging Procedures 14. . . . . . . . . . . . . . .
System Operation 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Homeowner Information 19. . . . . . . . . . . . . . . . . . . . . . . .
Start−Up and Performance Checklist 20. . . . . . . . . . . . .
Shipping and Packing List
Check the unit for shipping damage and listed times below
are intact. If damaged, or if parts are missing, immediately
contact the last shipping carrier.
1  Assembled outdoor unit
1  Refrigerant flow control kit (Fixed Orifice)
13ACD Outdoor Unit
13ACD Air Conditioners, which will also be referred to in
this instruction as the outdoor unit, uses HCFC−22
refrigerant. This outdoor unit must be installed with a
matching indoor unit and line set as outlined in the Lennox
13ACD Engineering Handbook.
This outdoor unit is designed for use in systems that use
one of the following refrigerant metering devices:
Thermal expansion valve (TXV)
Fixed orifice
Litho U.S.A.
Question and Answer IconNeed help?

Do you have a question about the Lennox Merit Series13ACD and is the answer not in the manual?

Lennox Merit Series13ACD Specifications

General IconGeneral
SEER RatingUp to 13
Cooling StagesSingle-stage
Compressor TypeScroll
RefrigerantR-410A
Sound Level (Outdoor Unit)76 dB
Cooling Capacity Range1.5 to 5 tons
Voltage208/230V
TypeAir Conditioner
Warranty5-Year Limited Warranty on covered components

Summary

Installation and Unit Preparation

Shipping and Packing List

Verifies all components are present and undamaged before installation.

Unit Dimensions and General Information

Provides physical size specifications and general operational guidance.

Refrigerant System Preparation

Service Valve Operation

Procedures for operating angle and ball type service valves.

Recovering Refrigerant from Existing System

Safe procedures for removing refrigerant from an old unit.

Outdoor Unit Placement

Guidance on optimal outdoor unit placement for efficiency, sound, and safety.

Refrigerant Line Set Installation

Information on selecting, installing, and isolating refrigerant line sets.

Brazing Connections

Detailed procedure for brazing refrigerant line sets to the outdoor unit.

Metering Devices, Testing, and Evacuation

Metering Device Installation

Procedures for installing new TXV or fixed orifice metering devices.

Testing for Leaks

Methods to detect refrigerant leaks in the connected system.

Evacuating the System

Process for removing non-condensables and moisture from the system.

Electrical, Charging, and Start-Up

Electrical Connections

Guidelines for safe and correct electrical wiring of the unit.

Start-Up and Charging Procedures

Steps for initiating unit operation and verifying refrigerant charge.

Determining Charge Method

Explains how to select the correct refrigerant charging method.

Operation, Maintenance, and Checks

System Operation and Maintenance

How the system operates and recommended checks for upkeep.

Homeowner Information

Guidance for the end-user regarding unit operation and care.

Preservice Check

Preliminary checks to perform before calling for professional service.

Related product manuals