WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
IMPORTANT
This unit must be matched with an indoor coil as specied
with AHRI. For AHRI Certied system match-ups and
expanded ratings, visit www.LennoxPros.com. Coils
previously charged with HCFC-22 must be ushed.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
WARNING
Electric Shock Hazard. Can cause injury or
death. Unit must be properly grounded in
accordance with national and local codes.
Line voltage is present at all components
when unit is not in operation on units with
single-pole contactors. Disconnect all remote
electric power supplies before opening
access panel. Unit may have multiple power
supplies.
ML18XC2
Table of Contents
Installation Clearances ...................................................2
Model Number Identication ...........................................2
Dimensions .....................................................................3
Specications .................................................................4
Typical Unit Parts Arrangement ...................................... 5
Operating Gauge Set and Service Valves ......................5
Unit Placement ..............................................................7
Removing and Installing Louvered Panels .....................8
New or Replacement Line Set ........................................9
Brazing Connections ................................................... 11
Flushing Line Set and Indoor Coil ................................14
Installing Indoor Metering Device .................................15
Leak Test Line Set and Indoor Coil ..............................16
Evacuating Line Set and Indoor Coil ...........................17
Electrical .......................................................................18
System Operation .......................................................20
Maintenance ...............................................................20
Servicing Units Void of Charge ...................................22
Start-Up ......................................................................22
Service Literature
UNIT INFORMATION
100051
June 10, 2022
ML18XC2 (HFC-410A) SERIES OUTDOOR UNITS
General Information
These instructions are intended as a general guide and do
not supersede national or local codes in any way. Consult
authorities having jurisdiction before installation.
The Merit
®
ML18XC2 model is designed for use with HFC-
410A refrigerant only. This unit must be installed with an
approved indoor air handler or coil. For AHRI Certied
system match-ups and expanded ratings, visit www.Len-
noxPros.com.
This outdoor unit is designed for use in systems that use
the following refrigerant metering device:
Thermal expansion valve (TXV)
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 21 in this
instruction for information.
WARNING
To prevent serious injury or death:
1. Lock-out/tag-out before performing maintenance.
2. If system power is required (e.g., smoke detector
maintenance), disable power to blower, remove fan
belt where applicable, and ensure all controllers
and thermostats are set to the “OFF” position before
performing maintenance.
3. Always keep hands, hair, clothing, jewelry, tools, etc.
away from moving parts.
Question and Answer IconNeed help?

Do you have a question about the Lennox ML18XC2-036 and is the answer not in the manual?

Lennox ML18XC2-036 Specifications

General IconGeneral
TypeHeat Pump
Cooling Capacity36000 BTU/h
SEER RatingUp to 18
HSPF Rating9.5
RefrigerantR-410A
Compressor TypeScroll
Voltage208/230V
Heating Capacity (BTU/h)36000 BTU/h
Phase1
Unit Weight (Outdoor Unit)230 lbs
StagesSingle Stage

Summary

General Information and Safety Notices

Critical Safety and Handling Warnings

Covers installation, electrical, and handling safety precautions.

Installation Clearances

Unit Specifications

General and Electrical Specifications

Details refrigerant, coil, fan, electrical data, and safety requirements.

Service Valve Operation

Unit Placement and Mounting

Refrigerant Line Set Installation

Refrigerant Line Set Isolation

Brazing Line Set Connections

Brazing Safety Warnings

Highlights hazards like fire and chemical exposure during brazing.

Brazing Procedures

Manifold Gauge and Nitrogen Setup

How to connect gauges and use nitrogen for brazing.

Brazing Process and Cooling

Wrapping and Protecting Service Valves

Techniques for protecting valve seals with water-saturated cloths.

Flushing Line Set and Indoor Coil

Flushing Procedure with HCFC-22

Detailed steps for flushing the system using HCFC-22.

Installing Indoor Metering Device

Leak Testing Line Set and Indoor Coil

Connecting Gauge Set for Leak Test

How to connect the manifold gauge set for leak testing.

Leak Test Procedure with Nitrogen

Step-by-step process for pressurizing with nitrogen and detecting leaks.

Evacuating Line Set and Indoor Coil

Connecting Gauge Set for Evacuation

How to connect the manifold gauge and vacuum pump.

Evacuation Procedure and Leak Check

Steps for achieving proper vacuum levels and verifying system integrity.

Electrical Connections and Thermostat

Typical Wiring Diagram

Outdoor Unit Wiring

Details wiring connections for the outdoor unit components.

Maintenance Procedures

Servicing Units Void of Refrigerant

Unit Start-Up Procedures

Pre-Start-Up Checks

Checking fan binding, wiring, and voltage before starting.

Starting the Unit and Verifying Operation

Procedures for starting the unit and confirming correct operation and refrigerant charge.

Start-Up and Performance Checklist

Initial Start-Up Checks

Recording customer info, refrigerant type, and amp readings.

Cooling Mode Performance Metrics

Measuring suction/liquid pressure, temperature drop, subcooling, and approach.

Related product manuals