Page 41
FIGURE 45
FurnaceCondensate
Drain
Connection
From Evaporator Coil
Optional
Condensate Trap With Optional Overflow Switch
Field Provided Vent
1” min. 2” max. above
condensate drain.
FIGURE 46
ML296UHV with Evaporator
Coil Using a Common Drain
(1” min. to 2” Max.above
condensatedrain connection)
Condensate
Drain
Connection
Evaporator drain
line required
(Trap at coil is optional)
FIGURE 47
ML296UHV with Evaporator Coil Using a Common Drain
(Unit shown in horizontal lefthand discharge position)
Condensate Drain
Connection
(4” min. to 5” Max.above
condensatedrain
connection)
5’ max.
PVC Pipe Only
4”min
5”max
Evaporator
Coil
Drain
Pan
Piping from furnace and evaporator coil must slope down a minimum 1/4” per ft. toward trap
(Trap at coil is optional)