MINI-SPLIT SYSTEMS SERVICE MANUAL
CORP1602-L9
3/2017
Supersedes 10/2016
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss
of life.
Installation and service must be performed by a licensed professional HVAC installer (or equivalent) or service agency

Table of Contents

Other manuals for Lennox MLA018S4S-1P

Questions and Answers:

Lennox MLA018S4S-1P Specifications

General IconGeneral
Tonnage1.5 Tons
Cooling Capacity18, 000 BTU
RefrigerantR-410A
Voltage208/230V
Phase1
Fan SpeedVariable

Summary

Single and Multiple Zone Outdoor Units

Outdoor Unit Clearances

Shows required installation clearances for outdoor units.

Cassette Non-Ducted Indoor Units

M22 A, M33 A and M33 B Indoor Unit Clearances

Shows required installation clearances for cassette indoor units.

MMDA Ducted Indoor Units

MWMA and MWMB Wall Mounted Indoor Units

MCFA and MCFB Ceiling Floor Indoor Units

Indoor Unit Clearances

Shows required installation clearances for MCFA and MCFB indoor units.

Indoor Outdoor Unit Combinations

Refrigeration Pipe Work

MPA, MPB and MLA Outdoor Unit Connections and Line Set Usage

Outdoor Unit Diagrams

Indoor Unit Diagrams

Control Board Photos

Condensate Pipe Work Installation

Controls

Connection to Centralized Controller

Start-Up

Adding Refrigerant - Single-Zone Systems

Details refrigerant addition procedures for single-zone systems.

Adding Refrigerant - Multi-Zone Systems

Details refrigerant addition procedures for multi-zone systems.

Quick Reference Guide - Error Codes

EEPROM & Communication Errors (E0-E3)

Troubleshooting steps for EEPROM and communication errors.

Sensor Errors (E4, F1-F6)

Troubleshooting steps for temperature sensor errors.

Protection Errors (E5-E6, P1-P6)

Troubleshooting steps for protection-related errors.

Troubleshooting Outdoor Unit Error Codes

E0: Outdoor EEPROM Malfunction

Troubleshooting steps for E0 error (EEPROM malfunction).

E2: Communication Error

Troubleshooting steps for E2 error (communication error).

E3: IPM Communication Error

Troubleshooting steps for E3 error (IPM communication error).

E4: Temperature Sensor Error

Troubleshooting steps for E4 error (temperature sensor error).

E5: High or Low Voltage Protection

Troubleshooting steps for E5 error (voltage protection).

E6: PFC Module Protection

Troubleshooting steps for E6 error (PFC module protection).

E8: Outdoor DC Fan Motor Speed Error

Troubleshooting steps for E8 error (fan speed error).

F1-F6: Coil Temperature Sensor Errors

Troubleshooting steps for coil temperature sensor errors.

P1: High Pressure Switch Open

Troubleshooting steps for P1 error (high pressure switch).

P2: Low Pressure Switch Open

Troubleshooting steps for P2 error (low pressure switch).

P3: Outdoor Compressor Current Overload

Troubleshooting steps for P3 error (compressor overload).

P4: Compressor Drive Error

Troubleshooting steps for P4 error (compressor drive error).

P5: High Temperature Sensed at Outdoor Coil

Troubleshooting steps for P5 error (outdoor coil high temp).

P6: IPM Module or IGBT Over Current Protection

Troubleshooting steps for P6 error (IPM/IGBT protection).

Troubleshooting Indoor Unit Error Codes

CP & EEPROM Errors (CP, E0)

Troubleshooting steps for CP and E0 errors on indoor units.

Communication & Fan Speed Errors (E1, E3)

Troubleshooting steps for E1 and E3 errors (communication, fan speed).

Sensor & Refrigerant Errors (E4, E5, EC)

Troubleshooting steps for sensor and refrigerant errors.

Water-level & Other Errors (EE)

Troubleshooting steps for EE error (water-level alarm).

Component Troubleshooting

Component Protection

Capacity Request Calculations

Defrost Control and Theory

Defrost Termination