WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
WARNING
Electric Shock Hazard. Can cause injury or
death. Unit must be properly grounded in
accordance with national and local codes.
Line voltage is present at all components when
unit is not in operation on units with single-
pole contactors. Disconnect all remote electric
power supplies before opening access panel.
Unit may have multiple power supplies.
ML14XC1
3-PHASE
Table of Contents
Model Number Identication ...........................................2
Typical Serial Number Identication ...............................2
Specications ................................................................3
Electrical Data ...............................................................3
Unit Dimensions – Inches (mm) ....................................4
Typical Unit Parts Arrangement ..................................... 5
Operating Gauge Set and Service Valves ......................6
Installation ......................................................................8
Unit Placement ..............................................................8
Removing and Installing Louvered Panels ...................10
New or Replacement Line Set ...................................... 11
Brazing Connections ...................................................13
Flushing Line Set and Indoor Coil ................................16
Installing Indoor Metering Device .................................17
Leak Testing the System .............................................18
Evacuating Line Set and Indoor Coil ...........................19
Electrical – Circuit Sizing and Wire Routing ..................20
Maintenance ...............................................................24
Typical Field Wiring ......................................................26
Servicing Units Delivered Void of Charge ...................26
Unit Start-Up ...............................................................27
System Refrigerant .....................................................27
Service Literature
UNIT INFORMATION
Corp. 100047
April 21, 2022
ML14XC1 (HFC-410A) SERIES OUTDOOR UNITS (3-PHASE)
IMPORTANT
This unit must be matched with an indoor coil as specied
with AHRI. For AHRI Certied system match-ups and
expanded ratings, visit www.LennoxPros.com. Coils
previously charged with HCFC-22 must be ushed.
General Information
This ML14XC1 outdoor air conditioner with all-aluminum
coil is designed for use with HFC-410A refrigerant only.
This unit must be installed with an approved indoor air
handler or coil. For AHRI Certied system match-ups and
expanded ratings, visit www.LennoxPros.com. These in-
structions are intended as a general guide and do not su-
persede local codes in any way. Consult authorities hav-
ing jurisdiction before installation.
This outdoor unit is designed for use in systems that use
the following refrigerant metering device:
Thermal expansion valve (CTXV)
IMPORTANT: Special procedures are required for clean-
ing the aluminum coil in this unit. See page 24 in this man-
ual for information.

Other manuals for Lennox ML14XC1 Series

Question and Answer IconNeed help?

Do you have a question about the Lennox ML14XC1 Series and is the answer not in the manual?

Lennox ML14XC1 Series Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
EER Rating11.5
Cooling Capacity (BTU/h)18, 000 to 60, 000
Voltage208/230V
Phase1
Cooling Capacity1.5 - 5 tons
SEER RatingUp to 14

Summary

Installation Guidelines

Refrigerant Line Set Installation

Line Set Isolation Techniques

Provides methods for isolating refrigerant lines from structural contact.

Brazing Procedures

Brazing Safety and Material Guidelines

Covers safety precautions, hazards, and recommended brazing alloys.

Brazing Preparation and Gauge Connections

Explains line preparation and gauge set connections for brazing.

Brazing Process and Cooling

Describes valve protection, nitrogen flow, and cooling during brazing.

Flushing and Metering Device Installation

Flushing Line Set and Indoor Coil

Details the procedure for flushing the line set and indoor coil with HCFC-22.

Indoor Metering Device Installation

Explains TXV installation, sensing bulb placement, and equalizer line connection.

Leak Testing the System

System Leak Test Procedure

Outlines steps for testing the line set and indoor coil for leaks.

Evacuating the System

Gauge Setup and Evacuation Procedure

Describes gauge setup and the process to evacuate the system to a deep vacuum.

Electrical Connections and Wiring

Circuit Sizing and Wire Routing

Covers NEC/CEC compliance, wire sizing, and routing.

Servicing Units Void of Charge

Unit Startup and Refrigerant Handling