Table 21. Lennox S40 Smart Thermostat Alert Codes and Troubleshooting
E2A=Errors to Action, GF= Gas Furnace, AH=Air Handler, IU=Indoor unit (GF or AH), HP=Heat Pump, AC=Air Conditioner, OU=Outdoor Unit (AC or HP), PA=Pure Air S, ZA=Zone system,
SRS=Smart Room Sensor, TS=Thermostat , IAQ- IAQ Monitor and WE=Wi-Fi Extender
Alert
Code
Inverter
Flash
Code
Priority
Condition
Actual Displayed Alert
Text Under dealer control
center > Notications
Component or System Operational State and Troubleshooting Tip
How to clear
alert code
430 26
Service
Soon/Service
Urgent
OU Inverter
Compressor Startup
Fail
Compressor start-up failure.
If condition is detected, outdoor unit will stop (compressor and fan) – service soon condition.
Anti-short cycle is initiated.
If condition occurs 10 times within 60 consecutive minutes, the system will lockout – service urgent
condition.
Inverter LEDs will ash code 26.
Refer to the unit service documentation for detailed troubleshooting procedures.
Inverter ash code 26.
The sequence is:
Red LED: Two Flashes
Green LED: Six Flashes
NOTE: Inverter normal operations with no error code present is as follows. Red LED is ON and Green LED
is OFF.
Check refrigerant
Replace outdoor control board
Replace inverter.
To clear, disconnect
power to outdoor unit
and restart.
431 27
Service
Soon/Service
Urgent
OU Inverter PFC Fault
The inverter has detected a PFC circuit over-current condition.
Error occurs when PFC detects an over current condition of 100A peak.
If condition is detected, outdoor unit will stop (compressor and fan) – service soon condition.
Anti-short cycle timer is initiated.
If condition occurs 10 times within 60 consecutive minutes, the system will lockout – service urgent
condition.
Inverter LEDs will ash code 27.
Refer to the unit service documentation for detailed troubleshooting procedures.
Inverter ash code 27.
The sequence is:
Red LED: Two Flashes
Green LED: Seven Flashes
NOTE: Inverter normal operations with no error code present is as follows. Red LED is ON and Green LED
is OFF.
To clear, disconnect
power to outdoor unit
and restart.