II-PLACEMENT AND INSTALLATION

-
-
         
-
󰀨
-
-

TABLE 18
PIPING AND FITTINGS SPECIFICATIONS
 
 
 
 
 
 
 
 
 
 






PRIMER & SOLVENT CEMENT
ASTM
SPECIFICATION
 
 
 
 








CANADA PIPE & FITTING & SOLVENT
CEMENT
MARKING







UL 1738 CERTIFIED GAS VENTING SYSTEM




Primer
* Not approved as of 12-1-2022
CAUTION
Solvent cements for plastic pipe are ammable
liquids and should be kept away from all sources of
ignition. Do not use excessive amounts of solvent
cement when making joints. Good ventilation
should be maintained to reduce re hazard and to
minimize breathing of solvent vapors. Avoid contact
of cement with skin and eyes.
IMPORTANT
SL297UHNV exhaust and intake connections are
made of PVC. Use PVC primer and solvent cement
when using PVC vent pipe. When using ABS vent
pipe, use transitional solvent cement to make
connections to the PVC ttings in the unit.
-
       
        







          

Canadian Applications Only - Pipe, ttings, primer and
solvent cement used to vent (exhaust) this appliance must
be certied to ULC S636 and supplied by a single manu-
facturer as part of an approved vent (exhaust) system. In
addition, the rst three feet of vent pipe from the furnace
ue collar must be accessible for inspection.
NOTE - The intake coupling on the furnace is ABS ma-
terial. Use transitional solvent to make connections to
PVC pipe.
NOTE - Vent pipe must be installed with ue coupling
See FIGURE 19.