EasyManua.ls Logo

Lennox SLP98UHV - Technical Data and Accessories; Performance and Electrical Specifications

Lennox SLP98UHV
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SLP98UHV / Page 9
SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP98UH070XV36B SLP98UH090XV36C SLP98UH090XV48C
1
AFUE 97.0% 98.0% 97.5%
Maximum Input - Btuh 66,000 88,000 88,000
Output - Btuh 64,000 85,000 85,000
Temperature rise range - °F 50 - 80 60 - 90 50 - 80
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Minimum Input - Btuh 23,000 31,000 31,000
Output - Btuh 22,000 30,000 30,000
Temperature rise range - °F 35 - 65 35 - 65 35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5 0.5 / 1.5 0.5 / 1.5
High static - in. w.g. 0.8 0.8 0.8
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4
with furnished 90° street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt
with eld supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nominal diameter x width - in. 10 x 9 10 x 9 11 x 11
Motor output - hp 1/2 1/2 3/4
Tons of add-on cooling 2 - 3 2 - 3.5 2.5 - 4
Air Volume Range - cfm 339 - 1365 520 - 1360 528 - 1770
Electrical Data Voltage (Maximum Amps) 120 volts - 60 hertz - 1 phase
Blower motor full load amps 7.7 7.7 10.1
Maximum overcurrent protection 15 15 15
Shipping Data lbs. - 1 package 138 155 165
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Efciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
furnaces.
SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP98UH090XV60C SLP98UH110XV60C SLP98UH135XV60D
1
AFUE 98.2% 97.5% 97.5%
Maximum Input - Btuh 88,000 110,000 132,000
Output - Btuh 85,000 106,000 128,000
Temperature rise range - °F 50 - 80 50 - 80 55 - 85
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Minimum Input - Btuh 31,000 39,000 46,000
Output - Btuh 30,000 38,000 45,000
Temperature rise range - °F 35 - 65 35 - 65 35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5 0.5 / 1.5 0.5 / 1.5
High static - in. w.g. 0.8 0.8 0.8
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4
with furnished 90° street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt
with eld supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nominal diameter x width - in. 11 x 11 11 x 11 11 x 11
Motor output - hp 1 1 1
Tons of add-on cooling 3 - 5 3 - 5 3.5 - 5
Air Volume Range - cfm 375 - 2195 554 - 2125 634 - 2190
Electrical Data Voltage (Maximum Amps) 120 volts - 60 hertz - 1 phase
Blower motor full load amps 12.8 12.8 12.8
Maximum overcurrent protection 20 20 20
Shipping Data lbs. - 1 package 165 175 190
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Efciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
furnaces.

Other manuals for Lennox SLP98UHV