Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-036-230 TXV 35,600 16.50 14.00 C33-50/60C G61MPV-60C-110 3844495
XC17-036-230 TXV 35,600 16.50 14.00 C33-50/60C G61MPV-60C-111 3844497
XC17-036-230 TXV 35,600 16.70 14.00 C33-50/60C SL280UH090V60C 4036835
XC17-036-230 TXV 35,600 16.70 14.00 C33-50/60C SL280UH090XV60C 4235575
XC17-036-230 TXV 35,400 16.50 14.00 C33-50/60C SL280UH110V60C 4036841
XC17-036-230 TXV 35,400 16.50 14.00 C33-50/60C SL280UH110XV60C 4040547
XC17-036-230 TXV 35,200 16.50 14.00 C33-50/60C SLP98UH090V36C 4035369
XC17-036-230 TXV 35,600 16.50 13.70 C33-50/60C SLP98UH090V60C 4035370
XC17-036-230 TXV 35,600 16.50 14.00 C33-50/60C SLP98UH110V60C 4035371
XC17-036-230 TXV 36,200 17.00 14.20 C33-62C G61MPV-36C-090 3844500
XC17-036-230 TXV 36,600 16.70 14.20 C33-62C G61MPV-60C-090 3844502
XC17-036-230 TXV 36,600 16.50 14.00 C33-62C G61MPV-60C-091 3844503
XC17-036-230 TXV 36,600 17.00 14.20 C33-62C G61MPV-60C-110 3844504
XC17-036-230 TXV 36,600 17.00 14.20 C33-62C G61MPV-60C-111 3844506
XC17-036-230 TXV 36,600 17.20 14.50 C33-62C SL280UH090V60C 4036844
XC17-036-230 TXV 36,600 17.20 14.50 C33-62C SL280UH090XV60C 4235572
XC17-036-230 TXV 36,600 17.00 14.20 C33-62C SL280UH110V60C 4036848
XC17-036-230 TXV 36,600 17.00 14.20 C33-62C SL280UH110XV60C 4040544
XC17-036-230 TXV 36,400 17.00 14.20 C33-62C SLP98UH090V36C 4035372
XC17-036-230 TXV 36,200 17.00 14.50 C33-62C SLP98UH090V48C 4035373
XC17-036-230 TXV 36,800 17.00 14.20 C33-62C SLP98UH090V60C 4035374
XC17-036-230 TXV 36,600 17.20 14.50 C33-62C SLP98UH110V60C 4035375
XC17-036-230 TXV 35,800 15.20 13.00 C33-62C 3844357
XC17-036-230 TXV 34,600 16.20 13.70 CBX27UH-036 3844584
XC17-036-230 TXV 35,600 17.00 14.20 CBX27UH-042 3844585
XC17-036-230 TXV 33,800 15.00 12.70 CBX32M-030 3844580
XC17-036-230 TXV 34,000 15.00 12.70 CBX32M-036 3844581
XC17-036-230 TXV 34,000 15.00 12.70 CBX32M-042 3844582
XC17-036-230 TXV 35,200 15.70 13.20 CBX32M-048 3844583
XC17-036-230 TXV 34,200 15.70 13.20 CBX32MV-024/030 3844586
XC17-036-230 TXV 34,600 16.00 13.50 CBX32MV-036 3844587
XC17-036-230 TXV 35,800 17.00 14.50 CBX32MV-048 3844588
XC17-036-230 TXV 34,000 16.50 13.50 CBX40UHV-036 3844589
XC17-036-230 TXV 35,000 17.20 14.00 CBX40UHV-042 3844590
XC17-036-230 TXV 35,200 17.50 14.20 CBX40UHV-048 3844591
XC17-036-230 TXV 34,000 15.50 13.20 CH23-41 G61MPV-36B-045 3844533
XC17-036-230 TXV 34,000 15.70 13.20 CH23-41 G61MPV-36B-070 3844534
XC17-036-230 TXV 34,000 15.70 13.20 CH23-41 G61MPV-36B-071 3844536
XC17-036-230 TXV 34,200 16.20 13.70 CH23-41 G61MPV-36C-090 3844537
XC17-036-230 TXV 34,400 16.00 13.50 CH23-41 SL280UH070V36A 3946897
XC17-036-230 TXV 34,400 16.00 13.50 CH23-41 SL280UH070XV36A 4037960
XC17-036-230 TXV 34,200 16.50 13.70 CH23-41 SL280UH090V36B 3946898
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.