XC17 - 2 to 5 Ton Air Conditioner / Page 35
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-042-230 TXV 39,000 15.70 13.00 CH23-51 SL280UH090V60C 3946939
XC17-042-230 TXV 39,000 15.70 13.00 CH23-51 SL280UH090XV60C 4235513
XC17-042-230 TXV 39,000 15.50 12.70 CH23-51 SL280UH110V60C 3946940
XC17-042-230 TXV 39,000 15.50 12.70 CH23-51 SL280UH110XV60C 4040555
XC17-042-230 TXV 38,500 15.50 12.70 CH23-51 SLP98UH090V36C 4020848
XC17-042-230 TXV 39,000 15.50 12.70 CH23-51 SLP98UH090V48C 4020849
XC17-042-230 TXV 38,500 15.70 12.70 CH23-51 SLP98UH090V60C 4020850
XC17-042-230 TXV 39,000 15.70 12.70 CH23-51 SLP98UH110V60C 4020851
XC17-042-230 TXV 38,500 14.20 12.00 CH23-51 3844620
XC17-042-230 TXV 39,000 15.50 12.70 CH23-65 G61MPV-36C-090 3844829
XC17-042-230 TXV 39,000 15.70 12.70 CH23-65 G61MPV-60C-090 3844830
XC17-042-230 TXV 39,000 15.50 12.70 CH23-65 G61MPV-60C-091 3844831
XC17-042-230 TXV 39,500 15.70 13.00 CH23-65 G61MPV-60C-110 3844832
XC17-042-230 TXV 39,000 15.70 12.70 CH23-65 G61MPV-60C-111 3844833
XC17-042-230 TXV 39,500 16.00 13.00 CH23-65 G61MPV-60D-135 3844838
XC17-042-230 TXV 39,500 16.00 13.00 CH23-65 SL280UH090V60C 3946941
XC17-042-230 TXV 39,500 16.00 13.00 CH23-65 SL280UH090XV60C 4235514
XC17-042-230 TXV 39,000 15.70 12.70 CH23-65 SL280UH110V60C 3946942
XC17-042-230 TXV 39,000 15.70 12.70 CH23-65 SL280UH110XV60C 4040556
XC17-042-230 TXV 39,500 16.00 13.20 CH23-65 SL280UH135V60D 3946943
XC17-042-230 TXV 39,000 15.50 12.70 CH23-65 SLP98UH090V36C 4020852
XC17-042-230 TXV 39,000 15.70 12.70 CH23-65 SLP98UH090V48C 4020853
XC17-042-230 TXV 39,000 15.70 13.00 CH23-65 SLP98UH090V60C 4020854
XC17-042-230 TXV 39,500 15.70 13.00 CH23-65 SLP98UH110V60C 4020855
XC17-042-230 TXV 39,500 16.00 13.00 CH23-65 SLP98UH135V60D 4020856
XC17-042-230 TXV 38,500 14.50 12.00 CH23-65 3844621
XC17-042-230 TXV 40,500 16.00 13.00 CH23-68 G61MPV-36C-090 3844842
XC17-042-230 TXV 40,500 16.20 13.20 CH23-68 G61MPV-60C-090 3844843
XC17-042-230 TXV 40,000 16.00 13.00 CH23-68 G61MPV-60C-091 3844844
XC17-042-230 TXV 40,500 16.20 13.20 CH23-68 G61MPV-60C-110 3844845
XC17-042-230 TXV 40,500 16.20 13.20 CH23-68 G61MPV-60C-111 3844846
XC17-042-230 TXV 40,500 16.50 13.50 CH23-68 G61MPV-60D-135 3844851
XC17-042-230 TXV 41,000 16.50 13.50 CH23-68 SL280UH090V60C 3946944
XC17-042-230 TXV 41,000 16.50 13.50 CH23-68 SL280UH090XV60C 4235515
XC17-042-230 TXV 40,500 16.20 13.20 CH23-68 SL280UH110V60C 3946945
XC17-042-230 TXV 40,500 16.20 13.20 CH23-68 SL280UH110XV60C 4040557
XC17-042-230 TXV 41,000 16.50 13.50 CH23-68 SL280UH135V60D 3946946
XC17-042-230 TXV 40,500 16.00 13.20 CH23-68 SLP98UH090V36C 4020857
XC17-042-230 TXV 40,500 16.20 13.20 CH23-68 SLP98UH090V48C 4020858
XC17-042-230 TXV 40,000 16.20 13.20 CH23-68 SLP98UH090V60C 4020859
XC17-042-230 TXV 40,500 16.20 13.20 CH23-68 SLP98UH110V60C 4020860
XC17-042-230 TXV 41,000 16.50 13.50 CH23-68 SLP98UH135V60D 4020861
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.