XC17 - 2 to 5 Ton Air Conditioner / Page 42
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-048-230 TXV 47,500 15.20 12.50 C33-50/60C SL280UH090V60C 4036914
XC17-048-230 TXV 47,500 15.20 12.50 C33-50/60C SL280UH090XV60C 4235583
XC17-048-230 TXV 47,500 15.00 12.50 C33-50/60C SL280UH110V60C 4036915
XC17-048-230 TXV 47,500 15.00 12.50 C33-50/60C SL280UH110XV60C 4040577
XC17-048-230 TXV 47,500 15.00 12.20 C33-50/60C SLP98UH090V48C 4035408
XC17-048-230 TXV 47,500 14.70 12.20 C33-50/60C SLP98UH090V60C 4035409
XC17-048-230 TXV 47,500 15.00 12.50 C33-50/60C SLP98UH110V60C 4035410
XC17-048-230 TXV 47,000 14.50 12.00 C33-50/60C 3844927
XC17-048-230 TXV 48,000 15.50 12.70 C33-60D G61MPV-60D-135 3845003
XC17-048-230 TXV 48,500 15.50 12.70 C33-60D SL280UH135V60D 4036916
XC17-048-230 TXV 48,000 15.50 12.70 C33-60D SLP98UH135V60D 4035411
XC17-048-230 TXV 47,500 14.70 12.00 C33-60D 3844928
XC17-048-230 TXV 49,500 15.70 13.00 C33-62C G61MPV-60C-090 3845007
XC17-048-230 TXV 49,000 15.20 12.70 C33-62C G61MPV-60C-091 3845009
XC17-048-230 TXV 49,500 15.70 13.00 C33-62C G61MPV-60C-110 3845010
XC17-048-230 TXV 49,500 15.70 13.00 C33-62C G61MPV-60C-111 3845012
XC17-048-230 TXV 49,500 16.00 13.20 C33-62C SL280UH090V60C 4036917
XC17-048-230 TXV 49,500 16.00 13.20 C33-62C SL280UH090XV60C 4235584
XC17-048-230 TXV 49,500 16.00 13.20 C33-62C SL280UH110V60C 4036918
XC17-048-230 TXV 49,500 16.00 13.20 C33-62C SL280UH110XV60C 4040578
XC17-048-230 TXV 49,000 15.70 13.00 C33-62C SLP98UH090V48C 4035412
XC17-048-230 TXV 49,500 15.70 13.00 C33-62C SLP98UH090V60C 4035413
XC17-048-230 TXV 49,000 15.70 13.00 C33-62C SLP98UH110V60C 4035414
XC17-048-230 TXV 48,500 15.70 13.00 C33-62D G61MPV-60D-135 3845014
XC17-048-230 TXV 49,000 15.70 13.00 C33-62D SL280UH135V60D 4036919
XC17-048-230 TXV 48,500 15.70 13.00 C33-62D SLP98UH135V60D 4035415
XC17-048-230 TXV 48,500 14.70 12.20 C33-62D 3844929
XC17-048-230 TXV 48,000 15.50 12.70 CBX27UH-048 3845100
XC17-048-230 TXV 48,000 15.50 12.70 CBX27UH-060 3845101
XC17-048-230 TXV 48,000 15.20 12.50 CBX32M-048 3845098
XC17-048-230 TXV 48,000 15.00 12.50 CBX32M-060 3845099
XC17-048-230 TXV 48,000 15.50 13.00 CBX32MV-048 3845102
XC17-048-230 TXV 48,000 15.70 13.00 CBX32MV-060 3845103
XC17-048-230 TXV 48,000 16.00 13.00 CBX32MV-068 3845104
XC17-048-230 TXV 48,000 15.70 13.00 CBX40UHV-048 3845105
XC17-048-230 TXV 48,000 15.70 13.00 CBX40UHV-060 3845106
XC17-048-230 TXV 46,500 14.70 12.20 CH23-51 G61MPV-60C-090 3845037
XC17-048-230 TXV 46,500 14.50 12.00 CH23-51 G61MPV-60C-091 3845039
XC17-048-230 TXV 46,500 14.70 12.20 CH23-51 G61MPV-60C-110 3845040
XC17-048-230 TXV 46,500 14.70 12.20 CH23-51 G61MPV-60C-111 3845042
XC17-048-230 TXV 46,500 15.00 12.50 CH23-51 G61MPV-60D-135 3845044
XC17-048-230 TXV 46,500 15.00 12.50 CH23-51 SL280UH090V60C 3946975
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.