XC17 - 2 to 5 Ton Air Conditioner / Page 43
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-048-230 TXV 46,500 15.00 12.50 CH23-51 SL280UH090XV60C 4235521
XC17-048-230 TXV 46,500 15.00 12.50 CH23-51 SL280UH110V60C 3946976
XC17-048-230 TXV 46,500 15.00 12.50 CH23-51 SL280UH110XV60C 4040569
XC17-048-230 TXV 46,500 14.70 12.20 CH23-51 SLP98UH090V48C 4020895
XC17-048-230 TXV 46,500 14.70 12.20 CH23-51 SLP98UH090V60C 4020896
XC17-048-230 TXV 46,500 14.70 12.20 CH23-51 SLP98UH110V60C 4020897
XC17-048-230 TXV 46,500 15.00 12.50 CH23-51 SLP98UH135V60D 4020898
XC17-048-230 TXV 46,000 14.00 11.70 CH23-51 3844932
XC17-048-230 TXV 47,000 15.00 12.50 CH23-65 G61MPV-60C-090 3845048
XC17-048-230 TXV 47,000 14.70 12.20 CH23-65 G61MPV-60C-091 3845050
XC17-048-230 TXV 47,000 15.20 12.50 CH23-65 G61MPV-60C-110 3845051
XC17-048-230 TXV 47,000 15.00 12.50 CH23-65 G61MPV-60C-111 3845053
XC17-048-230 TXV 47,000 15.50 12.70 CH23-65 G61MPV-60D-135 3845055
XC17-048-230 TXV 47,000 15.20 12.70 CH23-65 SL280UH090V60C 3946977
XC17-048-230 TXV 47,000 15.20 12.70 CH23-65 SL280UH090XV60C 4235522
XC17-048-230 TXV 47,000 15.20 12.70 CH23-65 SL280UH110V60C 3946978
XC17-048-230 TXV 47,000 15.20 12.70 CH23-65 SL280UH110XV60C 4040570
XC17-048-230 TXV 47,000 15.20 12.50 CH23-65 SL280UH135V60D 3946979
XC17-048-230 TXV 47,000 15.20 12.50 CH23-65 SLP98UH090V48C 4020899
XC17-048-230 TXV 47,000 15.00 12.50 CH23-65 SLP98UH090V60C 4020900
XC17-048-230 TXV 47,000 15.20 12.50 CH23-65 SLP98UH110V60C 4020901
XC17-048-230 TXV 47,000 15.50 12.70 CH23-65 SLP98UH135V60D 4020902
XC17-048-230 TXV 46,500 14.20 11.70 CH23-65 3844933
XC17-048-230 TXV 49,000 15.70 13.00 CH23-68 G61MPV-60C-090 3845059
XC17-048-230 TXV 49,000 15.20 12.70 CH23-68 G61MPV-60C-091 3845061
XC17-048-230 TXV 49,000 15.70 13.00 CH23-68 G61MPV-60C-110 3845062
XC17-048-230 TXV 49,000 15.70 13.00 CH23-68 G61MPV-60C-111 3845064
XC17-048-230 TXV 49,000 16.00 13.20 CH23-68 G61MPV-60D-135 3845066
XC17-048-230 TXV 49,000 16.00 13.20 CH23-68 SL280UH090V60C 3946980
XC17-048-230 TXV 49,000 16.00 13.20 CH23-68 SL280UH090XV60C 4235523
XC17-048-230 TXV 49,000 16.00 13.20 CH23-68 SL280UH110V60C 3946981
XC17-048-230 TXV 49,000 16.00 13.20 CH23-68 SL280UH110XV60C 4040571
XC17-048-230 TXV 49,000 16.00 13.20 CH23-68 SL280UH135V60D 3946982
XC17-048-230 TXV 49,000 15.70 13.00 CH23-68 SLP98UH090V48C 4020903
XC17-048-230 TXV 49,000 15.70 13.00 CH23-68 SLP98UH090V60C 4020904
XC17-048-230 TXV 48,500 15.70 13.00 CH23-68 SLP98UH110V60C 4020905
XC17-048-230 TXV 49,000 16.00 13.20 CH23-68 SLP98UH135V60D 4020906
XC17-048-230 TXV 48,500 14.70 12.20 CH23-68 3844934
XC17-048-230 TXV 48,000 15.50 12.70 CH33-43 SL280UH090V48B 4016670
XC17-048-230 TXV 48,000 15.50 12.70 CH33-43 SL280UH090XV48B 4038844
XC17-048-230 TXV 47,000 14.70 12.20 CH33-44/48 SL280UH090V48B 4016671
XC17-048-230 TXV 47,000 14.70 12.20 CH33-44/48 SL280UH090XV48B 4038848
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.