XC17 - 2 to 5 Ton Air Conditioner / Page 44
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-048-230 TXV 47,500 15.00 12.20 CH33-48 G61MPV-60C-090 3845070
XC17-048-230 TXV 47,500 14.70 12.20 CH33-48 G61MPV-60C-091 3845072
XC17-048-230 TXV 47,500 15.00 12.50 CH33-48 G61MPV-60C-110 3845073
XC17-048-230 TXV 47,500 15.00 12.20 CH33-48 G61MPV-60C-111 3845075
XC17-048-230 TXV 47,500 15.20 12.50 CH33-48 SL280UH090V60C 3946983
XC17-048-230 TXV 47,500 15.20 12.50 CH33-48 SL280UH090XV60C 4235524
XC17-048-230 TXV 47,500 15.20 12.50 CH33-48 SL280UH110V60C 3946984
XC17-048-230 TXV 47,500 15.20 12.50 CH33-48 SL280UH110XV60C 4040572
XC17-048-230 TXV 47,500 15.00 12.50 CH33-48 SLP98UH090V48C 4020907
XC17-048-230 TXV 47,500 15.00 12.20 CH33-48 SLP98UH090V60C 4020908
XC17-048-230 TXV 47,500 14.50 12.00 CH33-48 3844935
XC17-048-230 TXV 48,500 15.20 12.70 CH33-49 G61MPV-60C-090 3845078
XC17-048-230 TXV 48,500 15.00 12.50 CH33-49 G61MPV-60C-091 3845080
XC17-048-230 TXV 48,500 15.20 12.70 CH33-49 G61MPV-60C-110 3845081
XC17-048-230 TXV 48,500 15.20 12.70 CH33-49 G61MPV-60C-111 3845083
XC17-048-230 TXV 48,500 15.50 12.70 CH33-49 SL280UH090V60C 3946985
XC17-048-230 TXV 48,500 15.50 12.70 CH33-49 SL280UH090XV60C 4235525
XC17-048-230 TXV 48,500 15.50 12.70 CH33-49 SL280UH110V60C 3946986
XC17-048-230 TXV 48,500 15.50 12.70 CH33-49 SL280UH110XV60C 4040573
XC17-048-230 TXV 48,500 15.20 12.70 CH33-49 SLP98UH090V48C 4020909
XC17-048-230 TXV 48,500 15.20 12.50 CH33-49 SLP98UH090V60C 4020910
XC17-048-230 TXV 48,500 15.20 12.70 CH33-49 SLP98UH110V60C 4020911
XC17-048-230 TXV 48,000 14.70 12.20 CH33-49 3844936
XC17-048-230 TXV 48,000 15.20 12.50 CH33-50/60C G61MPV-60C-090 3845086
XC17-048-230 TXV 48,000 15.00 12.20 CH33-50/60C G61MPV-60C-091 3845088
XC17-048-230 TXV 48,000 15.20 12.50 CH33-50/60C G61MPV-60C-110 3845089
XC17-048-230 TXV 48,500 15.20 12.50 CH33-50/60C G61MPV-60C-111 3845091
XC17-048-230 TXV 48,500 15.50 12.70 CH33-50/60C SL280UH090V60C 3946987
XC17-048-230 TXV 48,500 15.50 12.70 CH33-50/60C SL280UH090XV60C 4235526
XC17-048-230 TXV 48,000 15.20 12.70 CH33-50/60C SL280UH110V60C 3946988
XC17-048-230 TXV 48,000 15.20 12.70 CH33-50/60C SL280UH110XV60C 4040574
XC17-048-230 TXV 48,000 15.20 12.50 CH33-50/60C SLP98UH090V48C 4020912
XC17-048-230 TXV 48,000 15.00 12.50 CH33-50/60C SLP98UH090V60C 4020913
XC17-048-230 TXV 48,000 15.20 12.50 CH33-50/60C SLP98UH110V60C 4020914
XC17-048-230 TXV 48,000 14.70 12.20 CH33-50/60C 3844937
XC17-048-230 TXV 48,000 15.50 12.70 CH33-60D G61MPV-60D-135 3845093
XC17-048-230 TXV 48,000 15.50 12.70 CH33-60D SL280UH135V60D 3946989
XC17-048-230 TXV 48,000 15.50 12.70 CH33-60D SLP98UH135V60D 4020915
XC17-048-230 TXV 47,500 14.70 12.00 CH33-60D 3844938
XC17-048-230 TXV 48,500 15.50 12.70 CH33-62D G61MPV-60D-135 3845096
XC17-048-230 TXV 48,500 15.50 13.00 CH33-62D SL280UH135V60D 3946990
XC17-048-230 TXV 48,000 15.50 12.70 CH33-62D SLP98UH135V60D 4020916
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.