AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-060-230 TXV 57,000 15.50 12.70 CBX32MV-048 4096596
XC17-060-230 TXV 57,500 15.70 12.70 CBX32MV-060 4096597
XC17-060-230 TXV 57,000 16.00 13.00 CBX32MV-068 4096598
XC17-060-230 TXV 57,000 15.70 12.70 CBX40UHV-048 4096599
XC17-060-230 TXV 57,500 15.70 12.70 CBX40UHV-060 4096600
XC17-060-230 TXV 55,500 15.00 12.20 CH23-65 G61MPV-60C-090 4096623
XC17-060-230 TXV 55,000 15.00 12.20 CH23-65 G61MPV-60C-091 4096625
XC17-060-230 TXV 55,500 15.00 12.20 CH23-65 G61MPV-60C-110 4096626
XC17-060-230 TXV 55,500 15.00 12.20 CH23-65 G61MPV-60C-111 4096628
XC17-060-230 TXV 56,000 15.20 12.50 CH23-65 G61MPV-60D-135 4096631
XC17-060-230 TXV 55,500 15.50 12.50 CH23-65 SL280UH090V60C 4096620
XC17-060-230 TXV 55,500 15.50 12.50 CH23-65 SL280UH090XV60C 4235815
XC17-060-230 TXV 55,500 15.20 12.50 CH23-65 SL280UH110V60C 4096622
XC17-060-230 TXV 55,500 15.70 12.70 CH23-65 SL280UH135V60D 4096630
XC17-060-230 TXV 55,000 15.20 12.20 CH23-65 SLP98UH090V60C 4096624
XC17-060-230 TXV 55,500 15.00 12.20 CH23-65 SLP98UH110V60C 4096627
XC17-060-230 TXV 55,500 15.20 12.50 CH23-65 SLP98UH135V60D 4096632
XC17-060-230 TXV 55,500 14.70 12.00 CH23-65 4096605
XC17-060-230 TXV 58,000 15.70 12.70 CH23-68 G61MPV-60C-090 4096637
XC17-060-230 TXV 57,500 15.50 12.70 CH23-68 G61MPV-60C-091 4096639
XC17-060-230 TXV 58,500 15.70 13.00 CH23-68 G61MPV-60C-110 4096640
XC17-060-230 TXV 58,500 15.70 12.70 CH23-68 G61MPV-60C-111 4096642
XC17-060-230 TXV 58,500 16.00 13.00 CH23-68 G61MPV-60D-135 4096645
XC17-060-230 TXV 58,000 16.00 13.00 CH23-68 SL280UH090V60C 4096634
XC17-060-230 TXV 58,000 16.00 13.00 CH23-68 SL280UH090XV60C 4235816
XC17-060-230 TXV 58,000 16.00 13.00 CH23-68 SL280UH110V60C 4096636
XC17-060-230 TXV 58,500 16.00 13.00 CH23-68 SL280UH135V60D 4096644
XC17-060-230 TXV 57,500 15.70 13.00 CH23-68 SLP98UH090V60C 4096638
XC17-060-230 TXV 58,000 15.70 12.70 CH23-68 SLP98UH110V60C 4096641
XC17-060-230 TXV 58,000 16.00 13.00 CH23-68 SLP98UH135V60D 4096646
XC17-060-230 TXV 58,000 15.20 12.50 CH23-68 4096606
XC17-060-230 TXV 57,500 15.70 12.70 CH33-60D G61MPV-60D-135 4096648
XC17-060-230 TXV 57,000 15.70 12.70 CH33-60D SLP98UH135V60D 4096649
XC17-060-230 TXV 57,000 15.00 12.20 CH33-60D 4096603
XC17-060-230 TXV 57,000 15.50 12.50 CH33-62D G61MPV-60C-090 4185168
XC17-060-230 TXV 57,000 15.50 12.70 CH33-62D G61MPV-60C-110 4185170
XC17-060-230 TXV 57,500 15.70 12.70 CH33-62D G61MPV-60D-135 4096652
XC17-060-230 TXV 57,500 15.70 13.00 CH33-62D SL280UH090V60C 4185172
XC17-060-230 TXV 57,500 15.70 13.00 CH33-62D SL280UH090XV60C 4235819
XC17-060-230 TXV 57,000 15.70 12.70 CH33-62D SL280UH110V60C 4185173
XC17-060-230 TXV 57,500 15.70 12.70 CH33-62D SL280UH135V60D 4096651
XC17-060-230 TXV 57,500 15.70 12.70 CH33-62D SLP98UH135V60D 4096653
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.