AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-060-230 TXV 57,000 15.00 12.20 CH33-62D 4096604
XC17-060-230 TXV 56,500 15.20 12.20 CR33-50/60 G61MPV-60C-090 4096611
XC17-060-230 TXV 56,000 15.20 12.20 CR33-50/60 G61MPV-60C-091 4096613
XC17-060-230 TXV 57,000 15.20 12.50 CR33-50/60 G61MPV-60C-110 4096614
XC17-060-230 TXV 56,500 15.20 12.20 CR33-50/60 G61MPV-60C-111 4096616
XC17-060-230 TXV 57,000 15.50 12.50 CR33-50/60 SL280DF090V60C 4096608
XC17-060-230 TXV 57,000 15.50 12.70 CR33-50/60 SL280DF110V60C 4096610
XC17-060-230 TXV 56,000 15.20 12.50 CR33-50/60 SLP98DF090V60C 4096612
XC17-060-230 TXV 56,000 15.20 12.20 CR33-50/60 SLP98DF110V60C 4096615
XC17-060-230 TXV 56,000 15.00 12.20 CR33-50/60 4096601
XC17-060-230 TXV 57,000 15.50 12.50 CR33-60 G61MPV-60D-135 4096618
XC17-060-230 TXV 56,000 15.00 12.20 CR33-60 4096602
XC17-060-230 TXV 57,000 15.20 12.50 CX34-49 G61MPV-60C-090 4096570
XC17-060-230 TXV 56,500 15.20 12.50 CX34-49 G61MPV-60C-091 4096572
XC17-060-230 TXV 57,500 15.20 12.50 CX34-49 G61MPV-60C-110 4096573
XC17-060-230 TXV 57,500 15.20 12.50 CX34-49 G61MPV-60C-111 4096575
XC17-060-230 TXV 57,500 15.50 12.70 CX34-49 SL280UH090V60C 4096567
XC17-060-230 TXV 57,500 15.50 12.70 CX34-49 SL280UH090XV60C 4235813
XC17-060-230 TXV 57,000 15.50 12.70 CX34-49 SL280UH110V60C 4096569
XC17-060-230 TXV 56,500 15.20 12.50 CX34-49 SLP98UH090V60C 4096571
XC17-060-230 TXV 57,500 15.20 12.50 CX34-49 SLP98UH110V60C 4096574
XC17-060-230 TXV 57,500 15.20 12.50 CX34-49 4096562
XC17-060-230 TXV 57,500 15.70 12.70 CX34-60D G61MPV-60D-135 4096578
XC17-060-230 TXV 57,500 15.50 12.70 CX34-60D SL280UH135V60D 4096577
XC17-060-230 TXV 57,000 15.70 12.70 CX34-60D SLP98UH135V60D 4096579
XC17-060-230 TXV 57,000 15.00 12.20 CX34-60D 4096563
XC17-060-230 TXV 58,500 15.70 12.70 CX34-62C G61MPV-60C-090 4096584
XC17-060-230 TXV 58,000 15.70 12.70 CX34-62C G61MPV-60C-091 4096586
XC17-060-230 TXV 59,000 15.70 12.70 CX34-62C G61MPV-60C-110 4096587
XC17-060-230 TXV 59,000 15.70 12.70 CX34-62C G61MPV-60C-111 4096589
XC17-060-230 TXV 59,000 16.00 13.00 CX34-62C SL280UH090V60C 4096581
XC17-060-230 TXV 59,000 16.00 13.00 CX34-62C SL280UH090XV60C 4235814
XC17-060-230 TXV 58,500 16.00 13.00 CX34-62C SL280UH110V60C 4096583
XC17-060-230 TXV 58,000 15.70 12.70 CX34-62C SLP98UH090V60C 4096585
XC17-060-230 TXV 59,000 15.70 12.70 CX34-62C SLP98UH110V60C 4096588
XC17-060-230 TXV 59,000 15.50 12.70 CX34-62C 4096564
XC17-060-230 TXV 58,000 15.70 13.00 CX34-62D G61MPV-60D-135 4096592
XC17-060-230 TXV 57,500 16.00 13.20 CX34-62D SL280UH135V60D 4096591
XC17-060-230 TXV 58,000 15.70 13.00 CX34-62D SLP98UH135V60D 4096593
XC17-060-230 TXV 58,000 15.20 12.50 CX34-62D 4096565
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.