Page 32
XP16
CHARGING INFORMATION FOR MODEL XP16−XXX−230−04
Unit Charging Sticker − 580094−01, dated 05/09
Table 2 − Indoor Units Matchups and Subcooling Charge Levels (XP16−XXX−230−05)
INDOOR HEAT
MATCHUP PUMP
Target
Subcooling
*Add
charge
INDOOR HEAT
MATCHUP PUMP
Target
Subcooling
*Add
charge
INDOOR HEAT
MATCHUP PUMP
Target
Subcooling
*Add
charge
Heat
+
5ºF
Cool
+
1ºF
Heat
+
5ºF
Cool
+
1ºF
Heat
+
5ºF
Cool
+
1ºF
XP16–024
lb oz
XP16–036
lb oz
XP16–048
lb oz
CB30U–21/26 12 6 0 12 C33–44C 17 8 1 14 CB27UH−048 17 7 0 0
CB30U–31 13 9 1 12 CB27UH−036 17 8 2 4 CB27UH−060 17 7 0 0
CBX26UH–018 20 8 1 5 CB27UH−042 17 8 2 4 CB30U–51, –65 17 7 0 0
CBX26UH–024 20 8 1 5 CB30U–31 17 6 0 0
CBX32M–048,
–060
17 7 0 0
CB27UH−024 12 6 0 12 CB30U–41/46 17 8 2 4
CBX32MV–048,
–060
17 7 0 0
CB27UH−030 13 9 1 12 CBX26UH–030 25 8 1 14 CBX32MV–068 16 10 0 3
CBX32M–018/024 12 6 0 12 CBX26UH–036 25 8 1 14 CH23–68 15 13 0 7
CBX32M–030 13 9 1 12 CBX32M–030 17 6 0 0 CH33–60D–2F 18 4 0 2
CBX32MV–024/030 13 9 1 12 CBX32M–036 17 8 2 4 CH33–62D–2F 15 10 0 4
CBX32MV–036 12 9 0 10 CBX32MV–024/030 17 6 0 0 CR33–60 40 4 0 2
CBX40UHV–024,
−030
13 9 1 12 CBX32MV–036 17 8 2 4 CX34–60D–6F 18 4 0 2
CBX40UHV–036 12 9 0 10
CBX40UHV–024,
−030
17 6 0 0 CX34–62D–6F 16 8 0 2
CH33–25B 17 4 0 0
CBX40UHV–036,
−042
17 8 2 4 XP16–060 lb oz
CH33–36A–2F 12 6 0 10 CH23–51 17 7 0 13 CB27UH−060 13 10 2 1
CH33–36B–2F 17 4 0 0 CH23–65 12 8 1 10 CBX26UH–060 13 14 3 5
CH33–36C–2F 12 7 1 2 CH33–42B–2F 17 7 0 13 CBX32M–060 13 10 2 1
CR33–24A/B–F 20 4 0 0 CH33–44/48B–2F 12 8 1 8 CBX32MV–060 13 10 2 1
CR33–30/36A/B/C–F 20 8 1 6 CH33–48C–2F 10 8 1 6 CBX32MV–068 13 12 2 9
CR33–48 21 9 0 3 CH33–43B 9 10 1 6 CH23–68 13 14 3 3
CX34–25A/B–6F 12 6 0 12 CH33–49C 9 10 1 6 CH23–65 18 2 0 0
CX34–31A/B–6F 20 9 1 12 CR33–48B/C–F 25 8 2 0 CH33–60D–2F 15 6 1 3
CX34–36A/B/C–6F 17 5 0 5 CR33–50/60C–F 25 9 0 14 CH33–62D–2F 13 12 2 10
CX34–38A/B–6F SN be-
fore 6007K
31 7 0 8
CX34–38A/B–6F SN be-
fore 6007K
31 7 1 5 CR33–50/60C–F 30 6 1 3
CX34–38A/B–6F SN
6007K and after
10 8 0 11
CX34–38A/B–6F SN
6007K and after
10 8 1 12 CR33–60D–F 30 6 1 3
CX34–19 18 4 0 1 CX34–43B/C–6F 10 8 1 6 CX34–49C–6F 13 9 1 14
SN indicates coil serial number. CX34–60D 9 9 0 14 CX34–60D–6F 15 6 1 3
*Amount of charge required in additional to charge shown on unit nameplate. (Remem-
ber to consider lin
e set length difference.)
CX34–62C–6F 13 11 2 6
CX34–62D–6F 13 11 2 5