Model Number identification
P 21 XXX− −
Unit Type
P = Heat Pump
Series
Nominal Cooling Capacity
024 = 2 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons
Minor Revision Number
230
Voltage
230 = 208/230V-1ph-60hz
Refrigerant Type
X = R-410A
X
−02
Typical Serial Number Identification
8 09 C
Year Code
08 = 2008
09 = 2009
10 = 2010
Month Code
A = January
B = February
C = March
05716
5 (or 6) Digit Unique Number
Location Code
19 = Saltillo, Mexico
58 = Marshalltown, IA
5
Specifications
Model Number
Unit Outdoor Fan
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter - inches.
XP21-024-230-01, -02, -03, -04, -05 67 11 lbs. 0 oz. 5 26.1
XP21-024-230-06 67 10 lbs. 10 oz. 5 26.1
Model Number
Unit Outdoor Fan
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter - inches.
XP21-036-230-01, -02, -03, -04 72 11 lbs. 0 oz. 5 26.1
XP21-036-230-05 72 10 lbs. 10 oz. 5 26.1
Model Number
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter - inches.
XP21-048-230-01, -02, -03 73 14 lbs. 0 oz. 5 26.1
XP21-048-230-04 73 13 lbs. 0 oz. 5 26.1
XP21-048-230-05 73 12 lbs. 10 oz. 5 26.1
Model Number
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter - inches.
XP21-060-230-01, -02, -03 73 14 lbs. 4 oz. 5 26.1
XP21-060-230-04 73 13 lbs. 2 oz. 5 26.1
XP21-060-230-05 73 12 lbs. 12 oz. 5 26.1
1
Tested according to AHRI Standard 270-2008 test conditions.
2
Refrigerant charge sufficient for 15 feet length of refrigerant lines.