Cable storage | Stage 3
0a 0b
P1 P2
EXP1 EXP2
0c 0d
0f
0e
0a 0b
P1 P2
EXP1 EXP2
0c 0d 0f0e
21 43
21 43
Example A: A DE4000H controller shelf with two DE600S
drive shelves in a standard SAS configuration
Example B: A DE4000H controller shelf with one DE600S
drive shelf in a standard SAS configuration
Example: Power connections are on the rear of the shelf.
Cable the Shelves
Cable the system according to your configuration.
Examples are shown in this section. For more cabling
options, see ThinkSystem DE-Series Hardware Installa-
tion and Maintenance Guide for 4U Enclosures.
Power the Drive Shelves
Example
Cable a controller shelf and
two drive shelves
Storage cables
Cable a controller shelf and
one drive shelf
Cable controller A to IOM A of the first drive shelf.
Cable IOM A of the first drive shelf to IOM A of
the second drive shelf.
Cable IOM B of the first drive shelf to IOM B of
the second drive shelf.
3
Cable controller B to IOM B of the second
drive shelf.
4
CAUTION: Confirm the drive shelf power switches are o.
3. Turn on the two power switches on the controller shelf.
4. Check the LEDs and seven-segment display on each controller.
During the boot sequence, the seven-segment display will display
various codes. After the controller has booted up, the shelf ID
will be displayed.
1. Connect the two power cables for each shelf to dierent
power distribution units (PDUs) in the cabinet or rack.
2. If you have drive shelves, turn on their two power switches
first. Wait 2 minutes before applying power to the controller shelf.
| Power Cables
0a 0b
P1 P2
EXP1 EXP2
0c 0d 0f0e
0a 0b
P1 P2
EXP1 EXP2
0c 0d
0f
0e
1 43
21 43
1
1
2
3
4
2
Example
Storage cables
Cable controller A to IOM A.
Cable controller B to IOM B.