EasyManua.ls Logo

Lenovo ThinkSystem DS2200 - User Manual

Lenovo ThinkSystem DS2200
159 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ThinkSystem DS Series and DS EXP/D3284
Hardware Installation and Maintenance Guide
Machine Type: 4619/4617/4599/4588/6413

Table of Contents

Questions and Answers:

Lenovo ThinkSystem DS2200 Specifications

General IconGeneral
BrandLenovo
ModelThinkSystem DS2200
CategoryStorage
LanguageEnglish

Summary

Safety guidelines

Safe handling

Provides precautions for safely handling and lifting the storage system components.

Operation

Important considerations for operating the enclosure system to ensure proper airflow and cooling.

Electrical safety

Details essential electrical safety requirements for operating the 2U and 5U enclosures.

Rack system safety precautions

Outlines safety measures for mounting and operating enclosures within a rack cabinet.

Installation

Installation checklist

Outlines the sequential steps required for successful enclosure installation and initial configuration.

Installing the 2 U enclosure

Provides a step-by-step procedure for attaching rail kit brackets and installing the 2U enclosure.

Installing the 5 U enclosure

Details the procedure for installing the 5U enclosure, including rail adjustments and rack door removal.

Connecting the controller enclosure and optional expansion enclosures

Explains how to connect controller enclosures with expansion enclosures, including supported configurations.

Grounding checks

Emphasizes the importance of proper grounding and electrical earth connections.

Host system requirements

Lists requirements for host computers, including multipathing support for fault tolerance.

Connecting the enclosure to hosts

Describes how to connect enclosures to hosts using various interface protocols.

CNC technology

Explains Converged Network Controller technology for selecting host interface protocols.

Host connection

Explains how to connect servers to controller enclosures via HBAs using appropriate cables.

Connecting a management host on the network

Details how to connect a management host to the storage system over an Ethernet network.

Updating firmware

Guides users on verifying and updating firmware for controller and expansion modules.

Configure controller network ports

Describes manual and DHCP configurations for controller network ports, including IPv4/IPv6.

Change the CNC port mode

Explains how to change the CNC port mode between FC, iSCSI, and mixed configurations.

Connecting two storage systems to replicate volumes

Details setting up replication between two storage systems for disaster recovery.

Operation

Powering on;powering off

Provides instructions for powering the enclosure system on and off, including correct order.

Accessing the SMC

Guides users on how to access the Storage Management Console for configuration and monitoring.

Configuring and provisioning the storage system

Explains how to configure and provision the storage system using the SMC, including replication setup.

Troubleshooting and problem solving

Initial start-up problems

Addresses common issues encountered during initial system setup and configuration.

Computer does not recognize the enclosure system

Offers solutions for when the computer fails to recognize the storage enclosure system.

Troubleshooting 2 U enclosures

Addresses common problems in 2U enclosures and their corresponding alarm conditions.

PCM Faults

Details symptoms, causes, and recommended actions for Power Cooling Module (PCM) faults.

Thermal alarm

Discusses thermal alarms, causes, and recommended actions for overheating or fan-related issues.

Troubleshooting 5 U enclosures

Addresses common problems in 5U enclosures and their corresponding alarm conditions.

Fault isolation methodology

Presents the basic methodology for locating faults within the storage system.

Basic steps

Outlines fundamental steps for gathering fault information and isolating problems.

Gather fault information

Emphasizes collecting comprehensive fault information, including reviewing reported faults and LEDs.

Review the event logs

Explains how to interpret event logs, severities, and search for fault causes.

Isolate the fault

Describes the process of isolating faults, especially in data paths, to pinpoint problematic components.

If the enclosure does not initialize

Provides troubleshooting steps if the enclosure fails to initialize during startup.

Dealing with hardware faults

Provides precautions and procedures for dealing with hardware faults and component replacement.

Isolating a host-side connection fault

Guides on troubleshooting host-side connection faults.

Isolating a controller module expansion port connection fault

Guides on troubleshooting faults related to controller module expansion ports.

Isolating replication faults

Provides information on troubleshooting replication faults.

Firmware updates

Explains the importance of verifying and updating firmware for system compatibility and performance.

Customer-replaceable units

CRUs addressing 2 U 12-drive chassis

Details the customer-replaceable units (CRUs) for 2U 12-drive chassis configurations.

Module removal and replacement

ESD precautions

Provides essential precautions and methods to prevent electrostatic discharge damage to components.

Preventing electrostatic discharge

Details specific actions to take to avoid static electricity damage when handling parts.

Grounding methods to prevent electrostatic discharge

Explains various grounding methods to ensure proper anti-static protection.

CRU replacement for 2 U chassis

Provides procedures for replacing customer-replaceable units (CRUs) in 2U chassis.

Replacing a power cooling module

Details the procedure for replacing a failed Power Cooling Module (PCM).

Removing a PCM

Step-by-step instructions for safely removing a Power Cooling Module (PCM).

Installing a PCM

Provides instructions for installing a new Power Cooling Module (PCM).

Replacing a drive carrier module

Details the procedure for replacing disk drive carrier modules, noting hot-swappability.

Removing a SFF drive carrier module

Explains how to remove Small Form Factor (SFF) drive carrier modules.

Installing a SFF drive carrier module

Provides instructions for installing Small Form Factor (SFF) drive carrier modules.

Replacing an IOM

Details procedures for replacing I/O modules (IOMs), including controller and expansion modules.

Shutting down a controller module

Provides instructions for safely shutting down controller modules using SMC or CLI.

Removing an IOM

Details the procedure for removing an I/O module (IOM) from the enclosure.

Installing an IOM

Provides instructions for installing a new I/O module (IOM) into the enclosure.

CRU replacement for 5 U chassis

Provides procedures for replacing customer-replaceable units (CRUs) in 5U chassis.

Replacing a DDIC

Details the procedure for replacing a Disk Drive in Carrier (DDIC) module.

Removing a DDIC

Step-by-step instructions for safely removing a DDIC from its slot.

Installing a DDIC

Provides instructions for installing a new DDIC into the enclosure.

Replacing a PSU

Details the procedure for replacing a failed Power Supply Unit (PSU).

Removing a PSU

Step-by-step instructions for safely removing a Power Supply Unit (PSU).

Installing a PSU

Provides instructions for installing a new Power Supply Unit (PSU).

Replacing an FCM

Details the procedure for replacing a Fan Cooling Module (FCM).

Removing an FCM

Step-by-step instructions for safely removing a Fan Cooling Module (FCM).

Installing an FCM

Provides instructions for installing a new Fan Cooling Module (FCM).

SFP option for CNC ports

Install an SFP transceiver

Provides a step-by-step procedure for installing an SFP transceiver into a CNC port.

Verify component operation

Explains how to verify the correct installation and operation of an SFP transceiver using LEDs.

Related product manuals