PCIe Gen1/Gen2/Gen3 Speed Selection
Item
Options
Description
Slot 1 (Display depending on
which riser card is installed.)
Gen1
Gen2
Gen3
Set the PCIe slot as Generation 1 or Generation 2 or
Generation 3.
Note: Some adapters may not operate correctly in Gen2
or Gen3. Make sure to power off and power on the
system for these settings to take effect.
Slot 2 (Display depending on
which riser card is installed.)
Gen1
Gen2
Gen3
Set the PCIe slot as Generation 1 or Generation 2 or
Generation 3.
Note: Some adapters may not operate correctly in Gen2
or Gen3. Make sure to power off and power on the
system for these settings to take effect.
Slot 7 (for RAID slot)
Gen1
Gen2
Gen3
Set the PCIe slot as Generation 1 or Generation 2 or
Generation 3.
Note: Some adapters may not operate correctly in Gen2
or Gen3. Make sure to power OFF and power ON the
system for these settings to take effect.
Console Redirection Settings
Item
Options
Description
COM Port 1
Enable
Disable
Enable or disable COM 1 device. If [Disable] is selected,
the associated COM1 terminal settings will be hidden.
Enable is the default setting.
COM Port 2
Enable
Disable
Enable or disable COM 2 device. If [Disable] is selected,
the associated COM 2 terminal settings will be hidden.
Enable is the default setting.
Console Redirection
Enable
Disable
Auto
Set remote console redirection preference to enable or
disable console redirection. While [Auto] is selected,
console redirection will be enabled automatically if IPMI
Serial over LAN status is active. Auto is the default
setting.
Serial Port Sharing
Enable
Disable
Enable the system Baseboard Management Controller to
allow access to the system serial port. If this option is set
to [Enable], the BMC will be allowed to control the serial
communication port as requested by remote control
commands.
If sharing is [Disable], the serial port will be assigned to
the BMC unless the “Serial Port Access Mode” is set to
[Disable].
Disable is the default setting.