3. If the problem persists, perform AC power cycle. (wait several seconds between AC power is off and
on)
4. Retry this operation again.
5. If the problem persists, contact technical support.
Service Action:
1. Review PD Steps.
2. Try to load the XCC factory default settings from the XCC web interface.
3. If problem persists, escalate to next level of support.
• FQXPMER0007I: BMC factory default settings loaded successfully
Severity: Info
User Action:
Information only; no action is required.
Service Action:
n/a
• FQXPMNM0001G: Failed to set new BMC network parameters.
Severity: Warning
User Action:
1. Ensure input parameters are valid.
2. Wait for one minute and retry the setting.
3. Restart BMC via supported method and reboot the system.
4. Retry the setting change.
5. Use UEFI setup to change parameters (optional).
Service Action:
1. Review PD Steps.
2. Verify XCC status
3. If problem persists, escalate to next level of support.
• FQXPMNM0002I: Set BMC network parameters to new values.
Severity: Info
User Action:
Information only; no action is required.
Service Action:
n/a
• FQXPMOS0001K: Bootx64.efi is not found. Failed to Boot OS.
Severity: Warning
Chapter 4. XClarity Provisioning Manager events 255