Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
6. If the problem persists, please contact technical support.
Service Action:
1. Download the update package for LXPM, UEFI, XCC and apply it using (onecli or XCC WEB).
2. Install OS using manual method.
3. If problem persists, escalate to next level of support.
• FQXPMOS0004K: BMC Communication Failed: EMMC2USB Mount Failure.
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. Reflash BMC firmware.
4. Retry OS deployment.
5. Perform AC reset or virtual reseat.
Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
6. If the problem persists, please contact technical support.
Service Action:
1. Download the update package for LXPM, UEFI, XCC and apply it using (onecli or XCC WEB).
2. Install OS using manual method.
3. If problem persists, escalate to next level of support.
• FQXPMOS0005K: BMC communication failed: DRIVER Mount Failure.
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. Reflash BMC firmware.
4. Retry OS deployment.
5. Perform AC reset or virtual reseat.
Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
6. If the problem persists, please contact technical support.
Chapter 4. XClarity Provisioning Manager events 257