EasyManua.ls Logo

Lenz DIGITAL PLUS SET-02 - User Manual

Lenz DIGITAL PLUS SET-02
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Welcome!
Thank you for purchasing our SET-02. We would like to congratulate
you on your acquisition of the Digital plus by Lenz
®
SET-02 and
we hope you will enjoy working with this model-railway control.
The purpose of this operating manual is to explain the use of the Set
and its components to you. In order to proceed as quickly as
possible to the pleasure of operating your model railway with DCC.
Begin by reading the section "First Steps". After you have operated
your first train you will be better able to follow the step by step
description of SET-02's entire range of functions. It is not necessary
to understand or use all the system's features. Select the set of
features you are comfortable with and enjoy your model railroad.
If you still have questions, for which you can not find the answers
even after reading this operating manual, please contact us. We will
be happy to help you. There are four different ways of contacting
Lenz Elektronik GmbH:
Europe North America
Postal
address:
Lenz Elektronik GmbH
Huettenbergstrasse 29
D-35398 Giessen
Lenz Agency
PO Box 143
Chelmsford, MA 01824
Phone ++49 (0) 6403 900 133 ++1 978 250 1494
Fax ++49 (0) 6403 900 155 ++1 978 250 1494
Email info@digital-plus.de support@lenz.com
All present and correct?
Please check, whether all the components of the SET-02 have been
delivered:
LH200 - Knob based Engineer's Throttle
LV200 - Power Station (Booster)
black coil cable with phone plugs at each end
one 4- and one 3-terminal green connector attached to the
rear of the LV200
one additional 4-terminal green connector
operating manual (this booklet)
If any component is missing, please ask your supplier for a
supplementary delivery.

Table of Contents

Questions and Answers

  • J
    Joann BonillaAug 11, 2025
    Why Lenz Remote Control locomotives do not run and turnouts/signals can't be switched, but LV200 LED shines green?
    • T
      theresaestradaAug 11, 2025
      This issue occurs when the connection between the power station, the track, and/or the switch decoder is interrupted, specifically if terminals J and K are not connected. To resolve this, check and correct these connections.
  • G
    Gregory PhillipsAug 19, 2025
    What to do if Lenz DIGITAL PLUS SET-02 locomotives do not run and LED flashes green?
    • S
      Sean GrayAug 19, 2025
      This can happen due to several reasons: 1. The connection between the LV200 and command station LH200 is broken, or there is a short circuit at terminals C and D. Check and correct these connections. 2. The emergency stop key has been pressed. Press the emergency stop key again. 3. You are in programming mode using a programming track. When finished programming, turn the power to the LH200 off and on.
  • P
    paulahansenAug 27, 2025
    What to do if Lenz DIGITAL PLUS SET-02 Remote Control locomotives do not run because LED shines constantly red?
    • Y
      ypageAug 27, 2025
      A constant red LED indicates a short-circuit on the track system or overloading. To fix this, address the short-circuit or divide the system into coverage areas and supply them with additional transformers.
  • S
    smithdeniseSep 3, 2025
    How to fix Lenz SET-02 Remote Control when it is not operational (LED on LV200 does not light up)?
    • P
      Pamela BennettSep 3, 2025
      If the LED on the LV200 does not light up, it means that the power supply is interrupted. This could be because the transformer is not plugged into an outlet, or the "U" and "V" wires are not connected to the transformer. To solve this, ensure that the transformer is on and hasn't overloaded or shut off, and check the wiring from the transformer to the LV200.