20
ENGLISH
Commissioning
5.2.2 TPDO mapping details (P466/P476)
WORD0 - DSP402 control word 0x6041
Bit P466 / P476 setting = 0
WORD0 - DSP402 control word 0x6041
Bit P466 / P476 setting = 1
0
Ready
0 = Not ready to switch on 1 = Ready to switch on
0
Ready
0 = Not ready to switch on 1 = Ready to switch on
1
Output Switch
0 = switch OFF 1 = switch ON
1
Output Switch
0 = switch OFF 1 = switch ON
2
Operation
0 = operation disabled 1 = operation enabled
2
Operation
0 = operation disabled 1 = operation enabled
3
Fault
0 = No fault 1 = Fault
3
Fault
0 = No fault 1 = Fault
4 Voltage Enable [= 1 (enabled) on drive] 4 Voltage Enable [= 1 (enabled) on drive]
5
Quick stop
0 = Quick stop active 1 = Quick stop not active
5
Quick stop
0 = Quick stop active 1 = Quick stop not active
6 Switch ON enabled [= 0 (disabled) on drive] 6 Switch ON enabled [= 0 (disabled) on drive]
7
Warning
0 = No Warning 1 = Warning
7
Warning
0 = No Warning 1 = Warning
8 Manufacturer specific 8 Manufacturer specific
9
Network
0 = Not Remote (Manual) 1 = Remote (Network)
9
Network
0 = Not Remote (Manual) 1 = Remote (Network)
10
Operation at Setpoint
0 = Setpoint not reached 1 = Setpoint reached
10
Operation at Setpoint
0 = Setpoint not reached 1 = Setpoint reached
11
Internal Limit
0 = Limit NOT active 1 = Internal limit active
11
Internal Limit
0 = Limit NOT active 1 = Internal limit active
12 Reserved 12 Reserved
13 Reserved 13 Reserved
14 Reserved 14 Reserved
15 Reserved 15 Reserved
WORD1
Signed actual output frequency
• RPM calculation based on P304 and P305
• Example 1: P304 = 60Hz; P305 = 1750 RPM
request setpoint forward (CW) at 25.0 HZ =
25.0 x 1750/60 = 729 = 0x02D9
• Example 2: P304 = 50Hz; P305 = 1390 RPM
request setpoint reverse (CCW) at 44.5 HZ =
-(44.5 x 1390/50) = -1237 = 0xFB2B