EasyManua.ls Logo

Lenze 482 - Technical Data; Controller-Specific Technical Data; Dimensions; Scope of Supply

Lenze 482
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
L
2 Technical data
2.1 Controller-specific data
Type 481 482 483 484 485
Output power P
el
[kW] 10.5 23 46 92 115
Mains frequency f [Hz] 50...60
Mains voltage V
3L
[V] 340...460
Armature voltage V
A
460 V for V
3L
= 400 V (1.15 x V
3L
)
Armature current I
A
[A] 23 50 100 200 250
Field voltage V
F
0.9 x V
L1, L2 (N)
Max. field current I
F [A]
810
Rated master voltage V
LN
[V] 10...180
Rated tacho voltage V
TN
[V] 10...180
Operating ambient
temperature
T
u
[°C] 0...45
Set-value
potentiometer
Type
R
10k /1W
lin.
ER00322194
Field fuse
Type
F 101 FF16A/500V
EFSFF0160AWB
Electronics fuse
Type
F 102
F 103
F 104
F1A/450V
5 x 25
EFSF_0010AVF
Weight approx. m [kg] 4.5 5.5 8.5 10.5 13
Chassis type E 33.481__E 33.482__E 33.483__E 33.484__E 33.485__E

Related product manuals