EasyManua.ls Logo

Lenze 7812 - Overload Indication; TRIP Relay

Lenze 7812
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ET4
6/fa
checked: 19.04.89 MB
33.0831
GB
page:
9
5.10
Qverload
indication
‚max SOmA
Umax
=27V
OL
-
The
open
collector
transistor used
tor the
overload
indication
is
enabled
in
case
of
an
overload
which
is
langer than
10 sec,
and
remains
in
this
state
as
long
as
there
is
an
overload.It
is
disabled
one second
after the unload.
The
threshold
of
the
overload
indication
can
be
changed
by
subseguent
programming
ot
the
device.
5.11
TRIP
relav
-
lt
the
inverter
switches
to
show
a
fault
condition,
the
TRIP relay
is
activated.
The
contact switches
from
30B
to 30A.
F
[3oA13
OB
1300
Coritact
capacity
250V/2A-

Related product manuals