EasyManuals Logo

Lenze 8400 StateLine C Hardware Manual

Lenze 8400 StateLine C
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
Mechanical installation
Standard devices in t he power range 3 ... 22 kW
Mounting i n ”cold plate” technique
5
130
EDS84ASC552 EN 10.0
StateLine, HighLine
8400GG106b
Fig. 5-33 Device dimensions
h b t h
1
h
2
b
1
t
1
g
1
g
2
[kW] [mm]
E84AVxxC3024xX0 3
270 174 141 318 366 140 128 6 5
E84AVxxC4024xXx 4
E84AVxxC5524xXx 5.5
E84AVxxC3024xB0 3
270 174 161 318 366 140 148 6 5
E84AVxxC4024xBx 4
E84AVxxC5524xBx 5.5