EasyManua.ls Logo

Lenze 8609 E.6x.6 Series - General Data

Lenze 8609 E.6x.6 Series
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
2 Technical data
2.1 General data
Mains voltage: 3 x 480 V AC, 45 to 65 Hz
Permissible voltage range: 330 ... 528 V
(alternatively 470 to 740 V DC supply)
Output voltage: 3 x 0 to V
mains
(V ~ f
d
with 400 V at 50 Hz, adjustable, mains-independent)
When using a mains choke, the maximum possible output voltage is
reduced to approx. 96 % of the mains voltage.
Output frequency: 0 ... 50 Hz, adjustable up to 480 Hz
Chopper frequency: 4 kHz factory setting, adjustable from 2 ... 16 kHz
Threshold of the integrated brake
chopper:
765 V DC in the DC bus
Enclosure: Steel-sheet housing, IP20 to DIN 40050
Ambient temperature: 0 to 50 °C during operation
(for rating see page 11)
-25 to 55 °C during storage
-25 to 70 °C during transport
Noise immunity: Severity class 4 to IEC 801-4
Permissible pollution: Pollution level
˝ 2 to VDE 0110, part 2. The inverter should not be exposed to
corrosive or explosive gases.
Permissible humidity: relative humidity 80 %, no condensation
Influence of installation altitude on
the rated current:
1000 m: 100 % rated current
2000 m: 95 % rated current
3000 m: 90 % rated current
4000 m: 85 % rated current

Table of Contents

Related product manuals