102
Code Name Parameter
(Factory settings are printed in bold)
Acceptance see
page
Your
settings
C008 Output signal
digital
frequency
-0- Output of input signals at X5
-2- Main set-value (C046/JOG)
-3- Ramp generator output
(main set-value)
-5- Total set-value
SH + PRG 90
C009* Controller
address (only
for LECOM)
1 1...99 SH + PRG 110
C010 Minimum field
frequency
0.0Hz 0.0...480Hz
(in steps of 0.1Hz from 0.0 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE 71
C011 Maximum field
frequency
50Hz 7.5...480Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE 71
C012 Acceleration
time
main set-value
5.0s 0.0...990s
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 990s)
ON-LINE 72
C013 Deceleration
time
main set-value
5.0s 0.0...990s
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 990s)
ON-LINE 72
C014 V/f
characteristic
-0- linear characteristic V f
d
-1- square characteristic V f
d
2
SH + PRG 68
C015 V/f rated
frequency
50Hz 7.5...960Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 960Hz)
ON-LINE 68,
70
C016 Voltage boost 0.0% 0... 40%
(in steps of 0.1%)
ON-LINE 69
C017 Threshold for
Q
min
function
2.0Hz 0.0...480Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE 87
C018 Chopping
frequency
-0- 1kHz (field frequency max. 120 Hz)
-1- 2kHz (field frequency max. 240 Hz)
-2- 4kHz variable
-3- 6kHz variable
-4- 8kHz variable
-5- 12kHz variable
-6- 16kHz variable
-7- 12kHz fixed (for motor supply filter)
-8- 16kHz fixed (for motor supply filter)
[SH + PRG] 91
C019 Threshold for
automatic DC
injection
braking
0.0Hz 0.0...480Hz
0.0Hz = automatic DC injection braking
switched off
(in steps of 0.1Hz from 0.0 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE 92
C020 I
0
set-value Rated set-value (P
Nmotor
= P
Ncopntroller
)
0.0...0.5 I
maxcontroller
(in steps of 0.1 A from 0.0 to 100 A
in steps of 1 A as of 100 A)
ON-LINE 70
C021 Slip
compensation
0.0% 0.0...20 %
(in steps of 0.1%)
ON-LINE 92
C022 I
max
limit I
maxcontroller
0.08...1.0 I
maxcontroller
(in steps of 0.1A to 100A
in steps of 1A ab 100A)
ON-LINE 87