106
Code Name Parameter
(Factory settings are printed in bold)
Acceptance see
page
Your
settings
C108 Gain for C110 1.00 -10.00...+10.00
(in steps of 0.01)
ON-LINE 89
C109 Offset for
C110
0mV -1000...+1000mV
(in steps of 1mV)
ON-LINE 89
C110 Preselection:
monitor output
-1- Analog output terminal 62
-2- Analog output terminal 63
SH + PRG 89
C111 Monitor signal
for C110
-0- No signal
-2- Ramp generator input
(Set-value 1, JOG frequency)
-5- Total set-value (total from main
set-value and set-value 2)
-6- Feedback of PI controller
-7- Output of PI controller
-9- Output frequency
-23- Motor current
-30- Motor voltage
-31- DC bus voltage
SH + PRG 89
C112 Preselection:
freely
assignable
digital input
-1- digital input E1
-2- digital input E2
... ...
-8- digital input E8
SH + PRG 78,
79
C113 Function for
C112
-0- No function
-1- Enable additional pair of ramp times
-2- Enable JOG frequencies
-3- Reset TRIP
-4- Set TRIP
-5- Activate DC injection braking
-7- Integral action component = 0
-9- Ramp generator stop
-10- Ramp generator input = 0
-13- Activate process control
-20- Select parameter set
-21- Load parameter set
[SH + PRG] 78,
79
C114 Polarity for
C113
-0- Input HIGH active
-1- Input LOW active
[SH + PRG] 78,
79
C115 Priority for
C113
-0- Function can be changed via C001
-1- Function can be activated via terminals
independently of C001
[SH + PRG] 78,
79
C116 Preselection:
freely
assignable
digital output
-1- Digital output A1
-2- Digital output A2
-3- Digital output A3
-4- Digital output A4
-5- Relay output K11/K14
SH + PRG 86,
87
C117 Function for
C116
-0- No function
-1- Output frequency smaller than
Q
min
-threshold
-3- Maximum current reached
-4- Ready
-5- Pulse inhibit
-6- Fault indication
-9- Set-value reached
-10- Feedback = set-value
-11- Feedback = 0
-14- Flying restart circuit active
-30- Process control active
-31- Process step 1 active
-32- Process step 2 active
-33- Process step 3 active
-34- Process step 4 active
-35- Process step 5 active
-36- Process step 6 active
-37- Process step 7 active
-38- Process step 8 active
SH + PRG 86,
87
C118 Polarity for
C117
-0- Output HIGH active
-1- Output LOW active
SH + PRG 86,
87