EasyManua.ls Logo

Lenze 9200 Series - Page 63

Lenze 9200 Series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
5.2. LECOM status messages
C068 Operating state
Bit no. Signal
0, 1, 2, 3
Operating fault
4, 5, 6, 7
Communication fault
8
RFR enable
9
Q
min
10
running
11
IMP
12
QSP
13
I
max
14
N
act
= N
set
C069 Controller state
Bit no. Signal
0
BALARM
1
CALARM
2
PCHG
3
REMOT
4
AUTO
5
RESET
6
XXX
7
RFR
15
TRIP
C067 Fault numbers of the operating faults (see "Service")
--- OC1 OC2 OC5 OUE OH1 OH2 U15 CCr Pr Sd2 EEr UEr
0 111215225152707172829192
Further information on the serial communication LECOM1
(LECOM-A/B) can be obtained from the Operating Instructions
LECOM-A/B.
For extensions, the following modules are available:
2101 Interface with mains isolation for RS422/RS485
2122/2123 Interface for optical fibres (LECOM-LI)