64
Code Name Parameter Accept-
ance
see
page
C005*
Configuration
-11-
-12-
-13-
-20-
-21-
-30-
-33-
Speed control
n
set
: analog, X5, terminals 7, 8
Speed control
n
set
: analog, X5, terminals 1, 2
Speed control
n
set
: Dig. Set X2
Speed control with corresponding
variable torque limitation
n
set
: analog X5, terminals 1, 2
M
set
: analog X5, terminals 7, 8
Speed control with corresponding
variable torque limitation
n
set
: Dig. Set X2
M
set
: analog, X5, terminals 7, 8
Torque control
M
set
: analog X5, terminals 1,2
Torque control with corresponding
variable speed limitation
n
set
: analog X5, terminals 7, 8
M
set
: analog X5, terminals 1,2
46
C009*
Controller
address
1
Bus participant number LECOM-A/B
Setting range: 1 - 99
10, 20, 99 reserved for broadcast
SH+PRG
C011
n
max
(maximum
speed)
3000
Setting range: 100...8000 rpm
Step: 1 rpm
ON-LINE
C012
T
ir
(acceleration
time)
0.01
Setting range: 0.00...990 s
Step: 0.01s from 0.00...1s
0.1s.from 1...10s
1s from 10...100s
10s from 100...990s
ON-LINE 48
C013
T
if
(deceleration
time)
0.01
Setting range: 0.00...990 s
Step: 0.01s from 0.00...1s
0.1s.from 1...10s
1s from 10...100s
10s from 100...990s
ON-LINE 48
C017*
Q
min
-treshold
10
Setting range: 0...8000 rpm
Step: 1 rpm
When the motor speed is lower than
the Q
min
-treshold, output Q
min
is set
to 0 V.
ON-LINE
C018*
f
chop
(Chopper
frequency)
-0-
-1-
f
chop
= 8 kHz
f
chop
= 16 kHz
57
C022
I
max
(maximum
current)
xxx Step: 0.1 A ON-LINE 48